- Towards FLASH proton therapy: the impact of treatment planning and machine characteristics on achievable dose ratesItem type: Conference Paper
Acta Oncologicavan de Water, Steven; Safai, Sairos; Schippers, Jacobus M.; et al. (2019) - Daily adaptive proton therapy - the key to innovative planning approaches for paranasal cancer treatmentsItem type: Journal Article
Acta OncologicaNenoff, Lena; Matter, Michael; Lindmar, Johanna H.; et al. (2019)Background: For proton therapy of paranasal tumors, field directions avoiding volumes that might change during therapy are typically used. If the plan is optimized on the daily anatomy using daily adapted proton therapy (DAPT) however, field directions crossing the nasal cavities might be feasible. In this study, we investigated the effectiveness of DAPT for enabling narrow-field treatment approaches. Material and methods: For five paranasal tumor patients, representing a wide patient spectrum, anatomically robust 4-field-star and narrow-field plans were calculated and their robustness to anatomical and setup uncertainties was compared with and without DAPT. Based on the nominal planning CTs, per patient up to 125 simulated CTs (simCTs) with different nasal cavity fillings were created and random translations and rotations due to patient setup uncertainties were further simulated. Plans were recalculated or re-optimized on all error scenarios, representing non-adapted and DAPT fractions, respectively. From these, 100 possible treatments (60 GyRBE, 30 fx) were simulated and changes in integral dose, target and organs at risk (OARs) doses evaluated. Results: In comparison to the 4-field-star approach, the use of narrow-fields reduced integral dose between 29% and 56%. If OARs did not overlap with the target, OAR doses were also reduced. Finally, the significantly reduced target coverage in non-adapted treatments (mean V95 reductions of up to 34%) could be almost fully restored with DAPT in all cases (differences <1%). Conclusions: DAPT was found to be not only an effective way to increase plan robustness to anatomical and positional uncertainties, but also opened the possibility to use improved and more conformal field arrangements. - Intensity modulated proton therapy plan generation in under ten secondsItem type: Conference Paper
Acta OncologicaMatter, Michael; Nenoff, Lena; Meier, Gabriel; et al. (2019)Background: Treatment planning for intensity modulated proton therapy (IMPT) can be significantly improved by reducing the time for plan calculation, facilitating efficient sampling of the large solution space characteristic of IMPT treatments. Additionally, fast plan generation is a key for online adaptive treatments, where the adapted plan needs to be ideally available in a few seconds. However, plan generation is a computationally demanding task and, although dose restoration methods for adaptive therapy have been proposed, computation times remain problematic. Material and methods: IMPT plan generation times were reduced by the development of dedicated graphical processing unit (GPU) kernels for our in-house, clinically validated, dose and optimization algorithms. The kernels were implemented into a coherent system, which performed all steps required for a complete treatment plan generation. Results: Using a single GPU, our fast implementation was able to generate a complete new treatment plan in 5–10 sec for typical IMPT cases, and in under 25 sec for plans to very large volumes such as for cranio-spinal axis irradiations. Although these times did not include the manual input of optimization parameters or a final clinical dose calculation, they included all required computational steps, including reading of CT and beam data. In addition, no compromise was made on plan quality. Target coverage and homogeneity for four patient plans improved (by up to 6%) or remained the same (changes <1%). No worsening of dose-volume parameters of the relevant organs at risk by more than 0.5% was observed. Conclusions: Fast plan generation with a clinically validated dose calculation and optimizer is a promising approach for daily adaptive proton therapy, as well as for automated or highly interactive planning. - Impact of beam angle choice on pencil beam scanning breath-hold proton therapy for lung lesionsItem type: Journal Article
Acta OncologicaGorgisyan, Jenny; Perrin, Rosalind; Lomax, Antony J.; et al. (2017)