Journal: BMC Musculoskeletal Disorders

Loading...

Abbreviation

BMC Musculoskelet Disord

Publisher

BioMed Central

Journal Volumes

ISSN

1471-2474

Description

Search Results

Publications 1 - 10 of 29
  • Farshad, Mazda; Furrer, Pascal Raffael; Wanivenhaus, Florian; et al. (2021)
    BMC Musculoskeletal Disorders
    Study design: A retrospective, single center, case-control study was performed. Objective: The present study employed patient-specific biomechanical modeling to find potential biomechanical differences after spinal fusion at L4/5 in patients with and without subsequent development of adjacent segment disease (ASD). Methods: The study population comprised patients who underwent primary spinal fusion at L4/5 and were either asymptomatic during > 4 years of follow-up (CTRL; n = 18) or underwent revision surgery for ASD at L3/4 (n = 20). Landmarks were annotated on preoperative and follow-up lateral radiographs, and specific musculoskeletal models were created using a custom-built modeling pipeline. Simulated spinal muscle activation and lumbar intervertebral shear loads in unfused segments were analyzed in upright standing and forward flexion. Differences between the pre- and postoperative conditions were computed for each patient. Results: The average postoperative muscle activity in the upright standing posture was 88.4% of the preoperative activity in the CTRL group (p < 0.0001), but did not significantly change from pre- to postoperatively in the ASD group (98.0%). The average shear load magnitude at the epifusional joint L3/4 during upright standing increased from pre- to postoperatively in the ASD group (+ 3.9 N, +/− 17.4 (n = 18)), but decreased in the CTRL group (− 4.6 N, +/− 23.3 (n = 20); p < 0.001). Conclusion: Patient-specific biomechanical simulation revealed that spinal fusion surgery resulted in greater shear load magnitude and muscle activation and therefore greater forces at the epifusional segment in those with ASD compared with those without ASD. This is a first report of patient-specific disc load and muscle force calculation with predictive merits for ASD.
  • Steiner, Thomas H.; Bürki, Alexander; Ferguson, Stephen J.; et al. (2012)
    BMC Musculoskeletal Disorders
    Background It has been demonstrated that frequency modulation of loading influences cellular response and metabolism in 3D tissues such as cartilage, bone and intervertebral disc. However, the mechano-sensitivity of cells in linear tissues such as tendons or ligaments might be more sensitive to changes in strain amplitude than frequency. Here, we hypothesized that tenocytes in situ are mechano-responsive to random amplitude modulation of strain. Methods We compared stochastic amplitude-modulated versus sinusoidal cyclic stretching. Rabbit tendon were kept in tissue-culture medium for twelve days and were loaded for 1h/day for six of the total twelve culture days. The tendons were randomly subjected to one of three different loading regimes: i) stochastic (2 – 7% random strain amplitudes), ii) cyclic_RMS (2–4.42% strain) and iii) cyclic_high (2 - 7% strain), all at 1 Hz and for 3,600 cycles, and one unloaded control. Results At the end of the culture period, the stiffness of the “stochastic” group was significantly lower than that of the cyclic_RMS and cyclic_high groups (both, p < 0.0001). Gene expression of eleven anabolic, catabolic and inflammatory genes revealed no significant differences between the loading groups. Conclusions We conclude that, despite an equivalent metabolic response, stochastically stretched tendons suffer most likely from increased mechanical microdamage, relative to cyclically loaded ones, which is relevant for tendon regeneration therapies in clinical practice.
  • Bolszak, Sylvain; Casartelli, Nicola C.; Impellizzeri, Franco M.; et al. (2014)
    BMC Musculoskeletal Disorders
    Background The need for valid and reproducible questionnaires to routinely assess the physical activity level of patients after total knee arthroplasty (TKA) is of particular concern in clinical settings. Aims of this study were to evaluate the validity and reproducibility of the physical activity scale for the elderly (PASE) questionnaire in TKA patients, with a particular view on gender differences. Methods A total of 50 elderly patients (25 women and 25 men aged 70 ± 6 years) following primary unilateral TKA were recruited. The reproducibility was evaluated by administering the PASE questionnaire during two occasions separated by 7 days. The construct (criterion) validity was investigated by comparing the physical activity level reported by patients in the PASE questionnaire to that measured by accelerometry. Reproducibility was evaluated using intraclass correlation coefficients (ICC3,1) for reliability and standard error of measurement (SEM) and smallest detectable change (SDC) for agreement, while validity was investigated with Pearson correlation coefficients. Results Reliability of the PASE total score was acceptable for men (ICC = 0.77) but not for women (ICC = 0.58). Its agreement was low for both men and women, as witnessed by high SEM (32% and 35%, respectively) and SDC (89% and 97%, respectively). Construct validity of the PASE total score was low in both men (r = 0.45) and women (r = 0.06). Conclusions The PASE questionnaire has several validity and reproducibility shortcomings, therefore its use is not recommended for the assessment of physical activity level in patients after TKA, particularly in women.
  • Nussbaumer, Silvio; Leunig, Michael; Glatthorn, Julia F.; et al. (2010)
    BMC Musculoskeletal Disorders
    Background The aims of this study were to evaluate the construct validity (known group), concurrent validity (criterion based) and test-retest (intra-rater) reliability of manual goniometers to measure passive hip range of motion (ROM) in femoroacetabular impingement patients and healthy controls. Methods Passive hip flexion, abduction, adduction, internal and external rotation ROMs were simultaneously measured with a conventional goniometer and an electromagnetic tracking system (ETS) on two different testing sessions. A total of 15 patients and 15 sex- and age-matched healthy controls participated in the study. Results The goniometer provided greater hip ROM values compared to the ETS (range 2.0-18.9 degrees; P < 0.001); good concurrent validity was only achieved for hip abduction and internal rotation, with intraclass correlation coefficients (ICC) of 0.94 and 0.88, respectively. Both devices detected lower hip abduction ROM in patients compared to controls (P < 0.01). Test-retest reliability was good with ICCs higher 0.90, except for hip adduction (0.82-0.84). Reliability estimates did not differ between the goniometer and the ETS. Conclusions The present study suggests that goniometer-based assessments considerably overestimate hip joint ROM by measuring intersegmental angles (e.g., thigh flexion on trunk for hip flexion) rather than true hip ROM. It is likely that uncontrolled pelvic rotation and tilt due to difficulties in placing the goniometer properly and in performing the anatomically correct ROM contribute to the overrating of the arc of these motions. Nevertheless, conventional manual goniometers can be used with confidence for longitudinal assessments in the clinic.
  • Fürnstahl, Philipp; Casari, Fabio A.; Ackermann, Joëlle; et al. (2020)
    BMC Musculoskeletal Disorders
    Background Legg–Calvé–Perthes (LCP) is a common orthopedic childhood disease that causes a deformity of the femoral head and to an adaptive deformity of the acetabulum. The altered joint biomechanics can result in early joint degeneration that requires total hip arthroplasty. In 2002, Ganz et al. introduced the femoral head reduction osteotomy (FHRO) as a direct joint-preserving treatment. The procedure remains one of the most challenging in hip surgery. Computer-based 3D preoperative planning and patient-specific navigation instruments have been successfully used to reduce technical complexity in other anatomies. The purpose of this study was to report the first results in the treatment of 6 patients to investigate whether our approach is feasible and safe. Methods In this retrospective pilot study, 6 LCP patients were treated with FHRO in multiple centers between May 2017 and June 2019. Based on patient-specific 3D-models of the hips, the surgeries were simulated in a step-wise fashion. Patient-specific instruments tailored for FHRO were designed, 3D-printed and used in the surgeries for navigating the osteotomies. The results were assessed radiographically [diameter index, sphericity index, Stulberg classification, extrusion index, LCE-, Tönnis-, CCD-angle and Shenton line] and the time and costs were recorded. Radiologic values were tested for normal distribution using the Shapiro–Wilk test and for significance using Wilcoxon signed-rank test. Results The sphericity index improved postoperatively by 20% (p = 0.028). The postoperative diameter of the femoral head differed by only 1.8% (p = 0.043) from the contralateral side and Stulberg grading improved from poor coxarthrosis outcome to good outcome (p = 0.026). All patients underwent acetabular reorientation by periacetabular osteotomy. The average time (in minutes) for preliminary analysis, computer simulation and patient-specific instrument design was 63 (±48), 156 (±64) and 105 (±68.5), respectively. Conclusion The clinical feasibility of our approach to FHRO has been demonstrated. The results showed significant improvement compared to the preoperative situation. All operations were performed by experienced surgeons; nevertheless, three complications occurred, showing that FHRO remains one of the most complex hip surgeries even with computer assistance. However, none of the complications were directly related to the simulation or the navigation technique.
  • Farshad, Mazda; Frey, Andrea; Jentzsch, Thorsten; et al. (2021)
    BMC Musculoskeletal Disorders
    Background Anterior scoliosis correction is a powerful technique with the disadvantage of a kyphotic effect on lumbar and thoracolumbar curves. We aimed to investigate whether a cognizant interposition of a rib graft anteriorly and at the concave side of the scoliotic curve causes significant fulcrum effect to enforce scoliosis correction and to reduce interfusional kyphosis in anterior scoliosis corrections. Methods Twenty otherwise comparable patients with lumbar and thoracolumbar adolescent idiopathic scoliosis (AIS) curves undergoing anterior short scoliosis correction with (n = 10) or without (n = 10, matched for age, gender and degree of deformity) fulcrum effect were retrospectively compared by means of radiographic measurements (sagittal and coronal profile, Cobb angles and intersegmental deformity correction angles) to evaluate the effect of this modified surgical technique. Results The overall amount of scoliosis correction was similar with 74 and 60% of initial curves of 57° and 53° in the case and control group respectively with a mean of 3 fused segments (4 screws). Statistically relevant differences were found for intersegmental coronal cobb angles at the apex of 20° to 3° and 17° to 9° with and without fulcrum, respectively (p < 0.05). Creation of kyphosis in the fused segments was reduced with an interfusional kyphotic sagittal cobb angle of 15° pre-operatively vs. 3° post-operatively compared to the control group (13° pre-operatively vs. 18° post-operatively), (p < 0.05). Conclusions Interfusional hyperkyphosis associated with anterior scoliosis correction for thoracolumbar/lumbar curves can be reduced with cognizant positioning of the bone autograft at the antero-lateral (concave) site in the intervertebral region to create a fulcrum effect.
  • Knols, Ruud H.; Aufdemkampe, Geert; de Bruin, Eling; et al. (2009)
    BMC Musculoskeletal Disorders
    Background Hand-held dynamometry is a portable and inexpensive method to quantify muscle strength. To determine if muscle strength has changed, an examiner must know what part of the difference between a patient's pre-treatment and post-treatment measurements is attributable to real change, and what part is due to measurement error. This study aimed to determine the relative and absolute reliability of intra and inter-observer strength measurements with a hand-held dynamometer (HHD). Methods Two observers performed maximum voluntary peak torque measurements (MVPT) for isometric knee extension in 24 patients with haematological malignancies. For each patient, the measurements were carried out on the same day. The main outcome measures were the intraclass correlation coefficient (ICC ± 95%CI), the standard error of measurement (SEM), the smallest detectable difference (SDD), the relative values as % of the grand mean of the SEM and SDD, and the limits of agreement for the intra- and inter-observer '3 repetition average' and the 'highest value of 3 MVPT' knee extension strength measures. Results The intra-observer ICCs were 0.94 for the average of 3 MVPT (95%CI: 0.86–0.97) and 0.86 for the highest value of 3 MVPT (95%CI: 0.71–0.94). The ICCs for the inter-observer measurements were 0.89 for the average of 3 MVPT (95%CI: 0.75–0.95) and 0.77 for the highest value of 3 MVPT (95%CI: 0.54–0.90). The SEMs for the intra-observer measurements were 6.22 Nm (3.98% of the grand mean (GM) and 9.83 Nm (5.88% of GM). For the inter-observer measurements, the SEMs were 9.65 Nm (6.65% of GM) and 11.41 Nm (6.73% of GM). The SDDs for the generated parameters varied from 17.23 Nm (11.04% of GM) to 27.26 Nm (17.09% of GM) for intra-observer measurements, and 26.76 Nm (16.77% of GM) to 31.62 Nm (18.66% of GM) for inter-observer measurements, with similar results for the limits of agreement. Conclusion The results indicate that there is acceptable relative reliability for evaluating knee strength with a HHD, while the measurement error observed was modest. The HHD may be useful in detecting changes in knee extension strength at the individual patient level.
  • Blomkvist, Andreas W.; Eika, Fredrik; de Bruin, Eling; et al. (2018)
    BMC Musculoskeletal Disorders
    Background: Force steadiness is a quantitative measure of the ability to control muscle tonus. It is an independent predictor of functional performance and has shown to correlate well with different degrees of motor impairment following stroke. Despite being clinically relevant, few studies have assessed the validity of measuring force steadiness. The aim of this study was to explore the reproducibility of handgrip force steadiness, and to assess age difference in steadiness. Method: Intrarater reproducibility (the degree to which a rating gives consistent result on separate occasions) was investigated in a test-retest design with seven days between sessions. Ten young and thirty older adults were recruited and handgrip steadiness was tested at 5%, 10% and 25% of maximum voluntary contraction (MVC) using Nintendo Wii Balance Board (WBB). Coefficients of variation were calculated from the mean force produced (CVM) and the target force (CVT). Area between the force curve and the target force line (Area) was also calculated. For the older adults we explored reliability using intraclass correlation coefficient (ICC) and agreement using standard error of measurement (SEM), limits of agreement (LOA) and smallest real difference (SRD). Results: A systematic improvement in handgrip steadiness was found between sessions for all measures (CVM, CVT, Area). CVM and CVT at 5% of MVC showed good to high reliability, while Area had poor reliability for all percentages of MVC. Averaged ICC for CVM, CVT and Area was 0.815, 0.806 and 0.464, respectively. Averaged ICC on 5%, 10%, and 25% of MVC was 0.751, 0.667 and 0.668, respectively. Measures of agreement showed similar trends with better results for CVM and CVT than for Area. Young adults had better handgrip steadiness than older adults across all measures. Conclusion: The CVM and CVT measures demonstrated good reproducibility at lower percentages of MVC using the WBB, and could become relevant measures in the clinical setting. The Area measure had poor reproducibility. Young adults have better handgrip steadiness than old adults.
  • Goldhahn, Sabine; Kralinger, Franz; Rikli, Daniel; et al. (2010)
    BMC Musculoskeletal Disorders
    Background: With an ever-increasing elderly population, orthopaedic surgeons are faced with treating a high number of fragility fractures. Biomechanical tests have demonstrated the potential role of osteoporosis in the increased risk of fracture fixation complications, yet this has not been sufficiently proven in clinical practice. Based on this knowledge, two clinical studies were designed to investigate the influence of local bone quality on the occurrence of complications in elderly patients with distal radius and proximal humerus fractures treated by open reduction and internal fixation. Methods/Design: The studies were planned using a prospective multicentre open cohort design and included patients between 50 and 90 years of age. Distal radius and proximal humerus fractures were treated with locking compression 2.4 mm and proximal humerus internal locking plates, respectively. Follow-up examinations were planned for 6 weeks, 3 and 12 months as well as a telephone interview at 6 months. The primary outcome focuses on the occurrence of at least one local bone quality related complication. Local bone quality is determined by measuring bone mineral density and bone mineral content at the contralateral radius. Primary complications are categorised according to predefined factors directly related to the bone/fracture or the implant/surgical technique. Secondary outcomes include the documentation of soft tissue/wound or general/systemic complications, clinical assessment of range of motion, and patient-rated evaluations of upper limb function and quality of life using both objective and subjective measures. Discussion: The prospective multicentre open cohort studies will determine the value of local bone quality as measured by bone mineral density and content, and compare the quality of local bone of patients who experience a complication (cases) following surgery with that of patients who do not (controls). These measurements are novel and objective alternatives to what is currently used. Trial registration numbers: Clinical Trials.gov NCT01144208 and NCT01143675.
  • Luomajoki, Hannu; Kool, Jan; de Bruin, Eling; et al. (2008)
    BMC Musculoskeletal Disorders
    Background To determine whether there is a difference between patients with low back pain and healthy controls in a test battery score for movement control of the lumbar spine. Methods This was a case control study, carried out in five outpatient physiotherapy practices in the German-speaking part of Switzerland. Twelve physiotherapists tested the ability of 210 subjects (108 patients with non-specific low back pain and 102 control subjects without back pain) to control their movements in the lumbar spine using a set of six tests. We observed the number of positive tests out of six (mean, standard deviation and 95% confidence interval of the mean). The significance of the differences between the groups was calculated with Mann-Whitney U test and p was set on <0.05. The effect size (d) between the groups was calculated and d>0.8 was considered a large difference. Results On average, patients with low back pain had 2.21(95%CI 1.94–2.48) positive tests and the healthy controls 0.75 (95%CI 0.55–0.95). The effect size was d = 1.18 (p < 0.001). There was a significant difference between acute and chronic (p < 0.01), as well as between subacute and chronic patient groups (p < 0.03), but not between acute and subacute patient groups (p > 0.7). Conclusion This is the first study demonstrating a significant difference between patients with low back pain and subjects without back pain regarding their ability to actively control the movements of the low back. The effect size between patients with low back pain and healthy controls in movement control is large.
Publications 1 - 10 of 29