Dirk Mohn
Loading...
16 results
Search Results
Publications 1 - 10 of 16
- Polymerization shrinkage behaviour of resin composites functionalized with unsilanized bioactive glass fillersItem type: Journal Article
Scientific ReportsPar, Matej; Mohn, Dirk; Attin, Thomas; et al. (2020)Previous work has shown that partial replacement of reinforcing fillers with unsilanized silica particles can diminish polymerization shrinkage stress of dental resin composites. The aim of the present study was to investigate whether such an effect can be attained by using unsilanized bioactive glass (BG). Incorporating BG fillers into resin composites is interesting due to their potential for exerting caries-preventive effects. Experimental light-curable composites with a total filler load of 77 wt% were prepared. Reinforcing fillers were partially replaced with 0–60 wt% of BG 45S5 and an experimental low-sodium fluoride-containing BG. The following properties were investigated: linear shrinkage, degree of conversion, shrinkage stress, maximum shrinkage stress rate, and time to achieve maximum shrinkage stress rate. The diminishing effect of BG 45S5 on shrinkage stress was mediated by a decrease in degree of conversion caused by this BG type. In contrast, as the degree of conversion remained unaffected by the experimental BG, the resulting shrinkage behaviour was governed by the effect of varying amounts of silanized and unsilanized fillers on material’s viscoelastic properties. The replacement of silanized reinforcing fillers with unsilanized BG did not reduce polymerization shrinkage stress unless the reduction was attained indirectly through a diminished degree of conversion. - Buffer Solution Reduces Acidic Toothpaste Abrasivity Measured in Standardized TestsItem type: Journal Article
Frontiers in Dental MedicineZehnder, Matthias; Masoch, Luca; Gubler, Andrea; et al. (2020)It has been speculated that the diluent used to test toothpaste abrasivity in standard tests may have an impact on their results, especially in the context of acidic toothpastes. This study tested whether an acidic toothpaste is indeed more abrasive than a neutral counterpart of otherwise identical composition, and whether this increased abrasivity is prevented by a buffered solution simulating saliva. Two experimental toothpastes of identical composition yet different pH (7.0 vs. 5.0) were prepared using standard ingredients. Subsequently, they were tested in standard absolute dentin abrasion and relative dentin abrasivity (RDA) experiments. To prepare slurries for these tests, deionized water as recommended by the International Organization for Standardization (ISO 11609:2017) was used, or a buffer solution containing bicarbonate and phosphate. The pH in these slurries was assessed and compared to the pH obtained in oral slurries of healthy individuals. Results showed that a significant (one-way ANOVA, p < 0.05) increase in mean absolute dentin abrasion and RDA values by 35 and 14%, respectively, was obtained when water was used as the diluent in conjunction with the acidic toothpaste as compared to the buffer solution. This was not the case with the neutral toothpaste. This result was explained by the finding that the buffer solution neutralized the pH in experimental slurries of the acidic toothpaste, while deionized water was unable to elevate the pH of the acidic toothpaste. That toothpaste was also neutralized in oral slurries. It was concluded that indeed the current ISO standard may result in a systematic overestimation of acidic toothpaste abrasivity. - Polymerization and shrinkage stress formation of experimental resin composites doped with nano- vs micron-sized bioactive glassesItem type: Journal Article
Dental Materials JournalJäger, Franziska; Mohn, Dirk; Attin, Thomas; et al. (2021)This study investigated the effect of adding bioactive glass 45S5 (BG) of different particle sizes to dental composite on resin polymerization and shrinkage stress formation. Commercial flowable composite was mixed with either 15 wt% BG fillers (nanometric, micrometric, or hybrid BG) or inert barium glass. Real-time linear polymerization shrinkage and shrinkage stress were recorded, and the degree of conversion was measured using FTIR spectroscopy. The commercial (unmodified) composite developed significantly higher linear shrinkage and shrinkage stress than the groups with 15 wt% added inert or BG fillers. After adding inert barium glass, the composite showed significantly higher linear shrinkage than when micrometric BG was added. The addition of bioactive or inert glass fillers did not affect the degree of conversion. Shrinkage stress can be reduced by adding inert or bioactive fillers (nano- and/or microparticulate BG) without affecting monomer conversion. - Directing Stem Cell Commitment by Amorphous Calcium Phosphate Nanoparticles Incorporated in PLGA: Relevance of the Free Calcium Ion ConcentrationItem type: Journal Article
International Journal of Molecular SciencesGröninger, Olivier; Hess, Samuel; Mohn, Dirk; et al. (2020)The microenvironment of mesenchymal stem cells (MSCs) is responsible for the modulation in MSC commitment. Nanocomposites with an inorganic and an organic component have been investigated, and osteogenesis of MSCs has been attributed to inorganic phases such as calcium phosphate under several conditions. Here, electrospun meshes and two-dimensional films of poly(lactic-co-glycolic acid) (PLGA) or nanocomposites of PLGA and amorphous calcium phosphate nanoparticles (PLGA/aCaP) seeded with human adipose-derived stem cells (ASCs) were analyzed for the expression of selected marker genes. In a two-week in vitro experiment, osteogenic commitment was not found to be favored on PLGA/aCaP compared to pure PLGA. Analysis of the medium revealed a significant reduction of the Ca2+ concentration when incubated with PLGA/aCaP, caused by chemical precipitation of hydroxyapatite (HAp) on aCaP seeds of PLGA/aCaP. Upon offering a constant Ca2+ concentration, however, the previously observed anti-osteogenic effect was reversed: alkaline phosphatase, an early osteogenic marker gene, was upregulated on PLGA/aCaP compared to pristine PLGA. Hence, in addition to the cell–material interaction, the material–medium interaction was also important for the stem cell commitment here, affecting the cell–medium interaction. Complex in vitro models should therefore consider all factors, as coupled impacts might emerge. - Bioactivity and Physico-Chemical Properties of Dental Composites Functionalized with Nano- vs. Micro-Sized Bioactive GlassItem type: Journal Article
Journal of Clinical MedicineOdermatt, Reto; Par, Matej; Mohn, Dirk; et al. (2020)Bioactive resin composites can contribute to the prevention of secondary caries, which is one of the main reasons for failure of contemporary dental restorations. This study investigated the effect of particle size of bioactive glass 45S5 on chemical and physical composite properties. Four experimental composites were prepared by admixing the following fillers into a commercial flowable composite: (1) 15 wt% of micro-sized bioactive glass, (2) 15 wt% of nano-sized bioactive glass, (3) a combination of micro- (7.5 wt%) and nano-sized (7.5 wt%) bioactive glass, and (4) 15 wt% of micro-sized inert barium glass. Hydroxyapatite precipitation and pH rise in phosphate-buffered saline were evaluated during 28 days. Degree of conversion and Knoop microhardness were measured 24 h after specimen preparation and after 28 days of phosphate-buffered saline immersion. Data were analyzed using non-parametric statistics (Kruskal–Wallis and Wilcoxon tests) at an overall level of significance of 5%. Downsizing the bioactive glass particles from micro- to nano-size considerably improved their capability to increase pH. The effect of nano-sized bioactive glass on degree of conversion and Knoop microhardness was similar to that of micro-sized bioactive glass. Composites containing nano-sized bioactive glass formed a more uniform hydroxyapatite layer after phosphate-buffered saline immersion than composites containing exclusively micro-sized particles. Partial replacement of nano- by micro-sized bioactive glass in the hybrid composite did not impair its reactivity, degree of conversion (p > 0.05), and Knoop microhardness (p > 0.05). It is concluded that downsizing bioactive glass particles to nano-size improves the alkalizing potential of experimental composites with no negative effects on their fundamental properties. - Dentine decalcification and smear layer removal by different ethylenediaminetetraacetic acid and 1-hydroxyethane-1,1-diphosphonic acid speciesItem type: Journal Article
International Endodontic JournalDeari, Shengjile; Mohn, Dirk; Zehnder, Matthias (2019) - Short- and Long-Term Dentin Bond Strength of Bioactive Glass-Modified Dental AdhesivesItem type: Journal Article
NanomaterialsOltramare, Ramona; Par, Matej; Mohn, Dirk; et al. (2021)This study investigated the short- and long-term effects of dental adhesives doped with nano-sized bioactive glass 45S5 (BAG) on the resin–dentin interfacial bond strength. Two etch-and-rinse adhesives (Adper Scotchbond Multi-Purpose (ASB) and Solobond Plus (SB)) and one self-etch adhesive (Clearfil SE Bond (CF)) were doped with different concentrations of BAG (5, 10, and 20 wt%). The unmodified (0 wt% BAG) commercial adhesives served as control groups. Dentin of 120 molars (n = 10 per group) was treated with the different adhesives, followed by buildups with a conventional composite restorative material. From each tooth, 14 sticks were prepared for micro-tensile bond strength (µTBS) testing. The sticks were stored in simulated body fluid at 37 °C and tested after 24 h or six months for µTBS and failure mode. Data were analyzed using Kruskal–Wallis tests in combination with post-hoc Conover-tests and Wilcoxon signed-rank tests at a level of significance of a = 0.05. After 24 h and six months, both etch-and-rinse adhesives with a low BAG content (up to 10 wt% for ASB and 5 wt% for SB) showed similar µTBSs as their respective control groups (0 wt% BAG). CF showed a significant decrease in µTBS even after addition of 5 wt% BAG. At a high concentration of added BAG (20 wt%), all three adhesives showed a significant decrease in µTBS compared to the unmodified controls. The CF control group showed significantly lower µTBS after 6 months of storage than after 24 h. In contrast, the µTBS of all CF groups modified with BAG was unaffected by aging. In conclusion, the tested etch-and-rinse adhesives can be modified with up to 5 wt% (SB), or 10 wt% (ASB) of BAG without reducing their short- and long-term dentin bond strength. Moreover, the addition of nano-sized BAG may prevent long-term bond strength deterioration of a self-etch adhesive. - Effects of endodontic irrigants on blood and blood-stained dentinItem type: Journal Article
HeliyonZollinger, Adrian; Attin, Thomas; Mohn, Dirk; et al. (2019)Objectives This study aimed to investigate bleaching effects of common endodontic irrigants on human whole blood and blood-stained dentin. Specifically, it was assessed whether sodium hypochlorite at a clinically recommended concentration (2.5% NaOCl) would bleach with similar efficacy as a peroxide-based irrigant at higher molarity (5% H2O2). Furthermore, the effects of a NaOCl-compatible chelator with a high affinity to iron (Dual Rinse HEDP) were investigated. Methods Human whole blood was mixed at a 1:20 ratio with either phosphate-buffered saline, 9% HEDP, 2.5% NaOCl, 2.5% NaOCl containing 9% HEDP, or 5% H2O2. Effects were assessed spectrometrically and photographically. Human dentin specimens were prepared with a methacrylate reservoir for liquids and a polished assessment side over 1 mm dentin thickness. Dentin was stained using human whole blood for 3 weeks and subsequently exposed to the irrigants for 60 min. Measurements were performed in the CIELAB color space. Results were compared using parametric tests with the alpha-type error set to 5%. Results When directly exposed, the solutions containing NaOCl completely discolored the blood, while the 5% H2O2 exerted a bleaching effect without complete dissolution of dissolved matter, and the pure 9% HEDP had no effect at all. The NaOCl solutions bleached blood-stained dentin more efficiently than H2O2 (p < 0.05). Conclusions Under the current conditions, the 2.5% NaOCl solution had a stronger bleaching effect on blood and blood-stained dentin than 5% H2O2. HEDP did not have any direct impact on blood color or NaOCl-derived bleaching. - Chemical, cytotoxic and genotoxic analysis of etidronate in sodium hypochlorite solutionItem type: Journal Article
International Endodontic JournalBallal, Nidambur V.; Das, S.; Rao, B.S.S.; et al. (2019) - Electrochemical Disinfection of Dental Implants - a Proof of ConceptItem type: Journal Article
PLoS ONEMohn, Dirk; Zehnder, Matthias; Stark, Wendelin J.; et al. (2011)Background Peri-implantitis has gained significant clinical attention in recent years. This disease is an inflammatory reaction to microorganisms around dental implants. Due to the limited accessibility, non-invasive antimicrobial strategies are of high interest. An unexpected approach to implant disinfection may evolve from electrolysis. Given the electrical conductivity of titanium implants, alkalinity or active oxidants can be generated in body fluids. We investigated the use of dental titanium implants as electrodes for the local generation of disinfectants. Our hypothesis was that electrolysis can reduce viable counts of adhering bacteria, and that this reduction should be greater if active oxidative species are generated. Methodology/Principal Findings As model systems, dental implants, covered with a mono-species biofilm of Escherichia coli C43, were placed in photographic gelatin prepared with physiological saline. Implants were treated by a continuous current of 0 - 10 mA for 15 minutes. The reduction of viable counts was investigated on cathodes and anodes. In separate experiments, the local change in pH was visualized using color indicators embedded in the gelatin. Oxidative species were qualitatively detected by potassium iodide-starch paper. The in situ generated alkaline environment around cathodic implants caused a reduction of up to 2 orders of magnitude in viable E. coli counts. On anodic implants, in contrast to cathodic counterparts, oxidative species were detected. Here, a current of merely 7.5 mA caused complete kill of the bacteria. Conclusions/Significance This laboratory study shows that electrochemical treatment may provide access to a new way to decontaminate dental implants in situ.
Publications 1 - 10 of 16