Agreement, Reliability, and Concurrent Validity of an Outdoor, Wearable-Based Walk Ratio Assessment in Healthy Adults and Chronic Stroke Survivors


Date

2022-06-20

Publication Type

Journal Article

ETH Bibliography

yes

Citations

Altmetric

Data

Abstract

Purpose: The walk ratio (WR)-the step-length/cadence relation-is a promising measure for gait control. GPS-running watches deliver clinically relevant outcomes including the WR. The aim of this study was to determine test-retest agreement, reliability and concurrent validity of an outdoor WR assessment using a GPS-running watch.Methods: Healthy adults and moderate-high functioning stroke survivors (>= 6 months), performed the 1 km-outdoor walk twice using a GPS-running watch (Garmin Forerunner 35, GFR35) and a Step Activity Monitor (SAM 3). Global cognition was assessed using the Montreal Cognitive Assessment. Test-retest agreement and reliability were assessed using Bland-Altman plots, standard error of measurement (SEM), intraclass correlation coefficients (ICCs) and smallest detectable changes (SDCs). Concurrent validity was determined by the mean difference (MD), standard error (SE), mean absolute percentage errors (MAPEs) and Spearman's Rho between GFR35 and SAM3. WR values of the two groups were compared by a Welch's test. A hierarchical multiple regression was performed with the WR as dependent variable and possible predictors as independent variables.Results: Fifty-one healthy adults [median: 60.0 (47.0, 67.0) years) and 20 stroke survivors [mean: 63.1 (12.4) years, median: 76 (30, 146) months post-stroke] were included. Test-retest agreement and reliability were excellent (SEM% <= 2.2, ICCs > 0.9, SDC% <= 6.1) and concurrent validity was high (MAPE < 5, rho > 0.7) for those walking >= 1 m/s. Walking < 1 m/s impaired accurate step counting and reduced agreement, reliability, and validity. The WR differed between healthy adults and stroke survivors (t = -2.126, p = 0.045). The hierarchical regression model including stroke and global cognition (Montreal Cognitive Assessment, 0-30) explained 25% of the WR variance (Delta R-2 = 0.246, p < 0.001). Stroke had no effect (beta = -0.05, p = 0.682), but global cognition was a predictor for an altered WR (beta = 0.44, p = 0.001).Discussion: The outdoor WR assessment using the GFR35 showed excellent test-retest agreement, reliability and concurrent validity in healthy adults and chronic stroke survivors walking at least 1 m/s. As the WR seems relevant in chronic stroke, future studies should further investigate this parameter.

Publication status

published

Editor

Book title

Volume

13

Pages / Article No.

857963

Publisher

Frontiers Media

Event

Edition / version

Methods

Software

Geographic location

Date collected

Date created

Subject

gait analysis; wearables; walk ratio; cognition; stroke; agreement; reliability; validity

Organisational unit

08758 - Trainingslehre / E. de Bruin check_circle

Notes

Funding

Related publications and datasets