Engineered Biological Neural Networks on High Density CMOS Microelectrode Arrays


Loading...

Date

2022-02-21

Publication Type

Journal Article

ETH Bibliography

yes

Citations

Altmetric

Data

Abstract

In bottom-up neuroscience, questions on neural information processing are addressed by engineering small but reproducible biological neural networks of defined network topology in vitro. The network topology can be controlled by culturing neurons within polydimethylsiloxane (PDMS) microstructures that are combined with microelectrode arrays (MEAs) for electric access to the network. However, currently used glass MEAs are limited to 256 electrodes and pose a limitation to the spatial resolution as well as the design of more complex microstructures. The use of high density complementary metal-oxide-semiconductor (CMOS) MEAs greatly increases the spatial resolution, enabling sub-cellular readout and stimulation of neurons in defined neural networks. Unfortunately, the non-planar surface of CMOS MEAs complicates the attachment of PDMS microstructures. To overcome the problem of axons escaping the microstructures through the ridges of the CMOS MEA, we stamp-transferred a thin film of hexane-diluted PDMS onto the array such that the PDMS filled the ridges at the contact surface of the microstructures without clogging the axon guidance channels. This method resulted in 23 % of structurally fully connected but sealed networks on the CMOS MEA of which about 45 % showed spiking activity in all channels. Moreover, we provide an impedance-based method to visualize the exact location of the microstructures on the MEA and show that our method can confine axonal growth within the PDMS microstructures. Finally, the high spatial resolution of the CMOS MEA enabled us to show that action potentials follow the unidirectional topology of our circular multi-node microstructure.

Publication status

published

Editor

Book title

Volume

16

Pages / Article No.

829884

Publisher

Frontiers Media

Event

Edition / version

Methods

Software

Geographic location

Date collected

Date created

Subject

bottom-up neuroscience; in vitro; CMOS; microelectrode arrays; engineered networks; PDMS microstructures

Organisational unit

Notes

Funding

165651 - Piezoresistive microchanneled SU-8 cantilevers using silver nanowires for increased detection sensitivity toward an automated multipipette tool (SNF)

Related publications and datasets