Kurzer Serviceunterbruch am Montag, 8. Dezember 2025, 12 bis 13 Uhr. Sie können in diesem Zeitraum keine neuen Dokumente hochladen oder bestehende Einträge bearbeiten. Das Login wird in diesem Zeitraum deaktiviert. Grund: Wartungsarbeiten // Short service interruption on Monday, December 8, 2025, 12.00 – 13.00. During this time, you won’t be able to upload new documents or edit existing records. The login will be deactivated during this time. Reason: maintenance work
 

Detection of volatile organic compounds with SESI and PTR high-resolution mass spectrometry: a feature comparison


METADATA ONLY
Loading...

Date

2020-08-05

Publication Type

Journal Article

ETH Bibliography

yes

Citations

Altmetric
METADATA ONLY

Data

Rights / License

Abstract

The analysis of volatiles is of high relevance for a wide range of applications from environmental air sampling, security screening to potential medical applications. High-resolution mass spectrometry methods offer a particular wide compound coverage, sensitivity and selectivity. On-line approaches allow direct analysis in real time without the need for sample preparation. For the first time, we systematically compared the analysis of volatile organic compounds with Secondary Electrospray Ionization (SESI) and Proton Transfer Reaction (PTR) high-resolution mass spectrometers. The selected instruments had comparable mass resolving power with 15’000 m/Δm or higher, which is particularly suitable for non-targeted analysis, for example, of exhaled breath. Exhalations from 14 healthy adults were analyzed simultaneously on both instruments. In addition, 97 reference standards from nine chemical classes were analyzed with a liquid evaporation system. Surprisingly, in breath, we reported more complementary than overlapping features. A clear mass dependence was observed for each method with the highest number of detected m/z features for SESI in the high mass region (m/z = 150 – 250) and for PTR in the low mass region (m/z = 50 – 150). SESI yielded a significantly higher numbers of peaks (828) compared to PTR (491) among a total of 1304 unique breath m/z features. The number of signals observed by both methods was lower than expected (134 features) with 796 unique SESI features and 374 unique PTR features. Hypotheses to explain the observed mass-dependent differences are proposed. © 2020 American Chemical Society

Publication status

published

Editor

Book title

Volume

31 (8)

Pages / Article No.

1632 - 1640

Publisher

American Chemical Society

Event

Edition / version

Methods

Software

Geographic location

Date collected

Date created

Subject

Organisational unit

03430 - Zenobi, Renato / Zenobi, Renato check_circle

Notes

Funding

Related publications and datasets

Is supplemented by: