Rotator Cuff Repair and Overlay Augmentation by Direct Interlocking of a Nonwoven Polyethylene Terephthalate Patch Into the Tendon: Evaluation in an Ovine Model


METADATA ONLY
Loading...

Date

2023-10

Publication Type

Journal Article

ETH Bibliography

yes

Citations

Altmetric
METADATA ONLY

Data

Rights / License

Abstract

Background: Arthroscopic repair of large rotator cuff tendon tears is associated with high rates of retear. Construct failure often occurs at the suture-tendon interface. Patch augmentation can improve mechanical strength and healing at this interface. Purpose: To introduce a novel technique for suture-free attachment of an overlaid patch and evaluate its biomechanical strength and biological performance. Study Design: Descriptive and controlled laboratory studies. Methods: An established ovine model of partial infraspinatus tendon resection and immediate repair was used. After a nonwoven polyethylene terephthalate patch was overlaid to the resected tendon, a barbed microblade was used to draw fibers of the patch directly into the underlying tissue. In vivo histological assessment of healing was performed at 6 and 13 weeks after implantation. Ex vivo models were used to characterize primary repair strength of the suture-free patch fixation to tendon. Additional ex vivo testing assessed the potential of the technique for patch overlay augmentation of suture-based repair. Results: The in vivo study revealed no macroscopic evidence of adverse tissue reactions to the interlocked patch fibers. Histological testing indicated a normal host healing response with minimal fibrosis. Uniform and aligned tissue ingrowth to the core of the patch was observed from both the tendon and the bone interfaces to the patch. There was no evident retraction of the infraspinatus muscle, lengthening of the tendon, or tendon gap formation over 13 weeks. Ex vivo testing revealed that direct patch interlocking yielded tendon purchase equivalent to a Mason-Allen suture (150 ± 58 vs 154 ± 49 N, respectively; P =.25). In an overlay configuration, fiber interlocked patch augmentation increased Mason-Allen suture retention strength by 88% (from 221 ± 43 N to 417 ± 86 N; P <.01) with no detectable difference in repair stiffness. Conclusion: Testing in an ovine model of rotator cuff tendon repair suggested that surgical interlocking of a nonwoven medical textile can provide effective biomechanical performance, support functional tissue ingrowth, and help avoid musculotendinous retraction after surgical tendon repair. Clinical Relevance: The novel technique may facilitate patch augmentation of rotator cuff repairs.

Permanent link

Publication status

published

Editor

Book title

Volume

51 (12)

Pages / Article No.

3235 - 3242

Publisher

SAGE

Event

Edition / version

Methods

Software

Geographic location

Date collected

Date created

Subject

Rotator cuff repair; Patch augmentation; Biomaterials; In vivo; Sheep model; Biomechanics

Organisational unit

03822 - Snedeker, Jess G. / Snedeker, Jess G. check_circle

Notes

Funding

Related publications and datasets