Biomechanical comparison of sagittal-parallel versus non-parallel pedicle screw placement


Date

2014-11

Publication Type

Journal Article

ETH Bibliography

yes

Citations

Altmetric

Data

Abstract

Background While convergent placement of pedicle screws in the axial plane is known to be more advantageous biomechanically, surgeons intuitively aim toward a parallel placement of screws in the sagittal plane. It is however not clear whether parallel placement of screws in the sagittal plane is biomechanically superior to a non-parallel construct. The hypothesis of this study is that sagittal non-parallel pedicle screws do not have an inferior initial pull-out strength compared to parallel placed screws. Methods The established lumbar calf spine model was used for determination of pull-out strength in parallel and non-parallel intersegmental pedicle screw constructs. Each of six lumbar calf spines (L1-L6) was divided into three levels: L1/L2, L3/L4 and L5/L6. Each segment was randomly instrumented with pedicle screws (6/45 mm) with either the standard technique of sagittal parallel or non-parallel screw placement, respectively, under fluoroscopic control. CT was used to verify the intrapedicular positioning of all screws. The maximum pull-out forces and type of failure were registered and compared between the groups. Results The pull-out forces were 5,394 N (range 4,221 N to 8,342 N) for the sagittal non-parallel screws and 5,263 N (range 3,589 N to 7,554 N) for the sagittal-parallel screws (p = 0.838). Interlevel comparisons also showed no statistically significant differences between the groups with no relevant difference in failure mode. Conclusion Non-parallel pedicle screws in the sagittal plane have at least equal initial fixation strength compared to parallel pedicle screws in the setting of the here performed cadaveric calf spine experiments.

Publication status

published

Editor

Book title

Volume

156 (11)

Pages / Article No.

2147 - 2151

Publisher

Springer

Event

Edition / version

Methods

Software

Geographic location

Date collected

Date created

Subject

Biomechanical comparison; Sagittal non-parallel; Pedicle screw; Pull-out force

Organisational unit

03822 - Snedeker, Jess G. / Snedeker, Jess G. check_circle

Notes

It was possible to publish this article open access thanks to a Swiss National Licence with the publisher.