dc.contributor.author
Yu, Ningbo
dc.contributor.author
Gassert, Roger
dc.contributor.author
Riener, Robert
dc.date.accessioned
2017-06-09T05:22:38Z
dc.date.available
2017-06-09T05:22:38Z
dc.date.issued
2010-07
dc.identifier.issn
1861-6410
dc.identifier.issn
1861-6429
dc.identifier.other
10.1007/s11548-010-0528-2
dc.identifier.uri
http://hdl.handle.net/20.500.11850/22225
dc.identifier.doi
10.3929/ethz-b-000022225
dc.format
application/pdf
dc.language.iso
en
dc.publisher
Springer
dc.rights.uri
http://rightsstatements.org/page/InC-NC/1.0/
dc.subject
MRI
dc.subject
Compatibility
dc.subject
Image quality
dc.subject
Electromagnetic interference
dc.subject
Design principles
dc.subject
Mechatronics
dc.subject
Robotics
dc.title
Mutual interferences and design principles for mechatronic devices in magnetic resonance imaging
dc.type
Journal Article
dc.rights.license
In Copyright - Non-Commercial Use Permitted
ethz.journal.title
International Journal of Computer Assisted Radiology and Surgery
ethz.journal.volume
6
ethz.journal.issue
4
ethz.journal.abbreviated
Int J CARS
ethz.pages.start
473
ethz.pages.end
488
ethz.version.deposit
publishedVersion
ethz.notes
Received 18 March 2010, Accepted 16 August 2010, Published online 2 September 2010. It was possible to publish this article open access thanks to a Swiss National Licence with the publisher
ethz.identifier.wos
ethz.identifier.nebis
005578473
ethz.publication.status
published
ethz.leitzahl
ETH Zürich::00002 - ETH Zürich::00012 - Lehre und Forschung::00007 - Departemente::02070 - Dep. Gesundheitswiss. und Technologie / Dep. of Health Sciences and Technology::03654 - Riener, Robert / Riener, Robert
ethz.leitzahl
ETH Zürich::00002 - ETH Zürich::00012 - Lehre und Forschung::00007 - Departemente::02070 - Dep. Gesundheitswiss. und Technologie / Dep. of Health Sciences and Technology::03827 - Gassert, Roger / Gassert, Roger
ethz.leitzahl.certified
ETH Zürich::00002 - ETH Zürich::00012 - Lehre und Forschung::00007 - Departemente::02070 - Dep. Gesundheitswiss. und Technologie / Dep. of Health Sciences and Technology::03827 - Gassert, Roger / Gassert, Roger
ethz.leitzahl.certified
ETH Zürich::00002 - ETH Zürich::00012 - Lehre und Forschung::00007 - Departemente::02070 - Dep. Gesundheitswiss. und Technologie / Dep. of Health Sciences and Technology::03654 - Riener, Robert / Riener, Robert
ethz.date.deposited
2017-06-09T05:22:47Z
ethz.source
ECIT
ethz.identifier.importid
imp59364cfb7013797602
ethz.ecitpid
pub:37040
ethz.eth
yes
ethz.availability
Open access
ethz.rosetta.installDate
2017-07-31T15:23:59Z
ethz.rosetta.lastUpdated
2022-03-28T08:51:09Z
ethz.rosetta.exportRequired
true
ethz.rosetta.versionExported
true
ethz.COinS
ctx_ver=Z39.88-2004&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.atitle=Mutual%20interferences%20and%20design%20principles%20for%20mechatronic%20devices%20in%20magnetic%20resonance%20imaging&rft.jtitle=International%20Journal%20of%20Computer%20Assisted%20Radiology%20and%20Surgery&rft.date=2010-07&rft.volume=6&rft.issue=4&rft.spage=473&rft.epage=488&rft.issn=1861-6410&1861-6429&rft.au=Yu,%20Ningbo&Gassert,%20Roger&Riener,%20Robert&rft.genre=article&rft_id=info:doi/10.1007/s11548-010-0528-2&