Show simple item record

dc.contributor.author
Thamsen, Bente
dc.contributor.author
Plamondon, Mathieu
dc.contributor.author
Granegger, Marcus
dc.contributor.author
Schmid Daners, Marianne
dc.contributor.author
Kaufmann, Rolf
dc.contributor.author
Neels, Antonia
dc.contributor.author
Meboldt, Mirko
dc.date.accessioned
2018-06-01T05:59:41Z
dc.date.available
2017-12-19T09:25:51Z
dc.date.available
2018-01-12T12:38:51Z
dc.date.available
2018-02-06T11:34:04Z
dc.date.available
2018-06-01T05:59:41Z
dc.date.issued
2018-05
dc.identifier.issn
1525-1594
dc.identifier.issn
0160-564X
dc.identifier.other
10.1111/aor.13074
en_US
dc.identifier.uri
http://hdl.handle.net/20.500.11850/222543
dc.language.iso
en
en_US
dc.publisher
Wiley
en_US
dc.subject
Rotary blood pump
en_US
dc.subject
Hydrodynamic bearing
en_US
dc.subject
Gap clearance
en_US
dc.subject
Blood damage
en_US
dc.subject
X-rays
en_US
dc.subject
Ventricular assist device
en_US
dc.subject
Radiography
en_US
dc.title
Investigation of the axial gap clearance in a hydrodynamically and passive magnetically levitated rotary blood pump using X-ray radiography
en_US
dc.type
Journal Article
dc.date.published
2018-01-17
ethz.journal.title
Artificial Organs
ethz.journal.volume
42
en_US
ethz.journal.issue
5
en_US
ethz.journal.abbreviated
Artif. Organs
ethz.pages.start
510
en_US
ethz.pages.end
515
en_US
ethz.identifier.wos
ethz.identifier.scopus
ethz.publication.place
Cambridge
en_US
ethz.publication.status
published
en_US
ethz.leitzahl
ETH Zürich::00002 - ETH Zürich::00012 - Lehre und Forschung::00007 - Departemente::02130 - Dep. Maschinenbau und Verfahrenstechnik / Dep. of Mechanical and Process Eng.::02665 - Inst. f. Design, Mat. und Fabrikation::03943 - Meboldt, Mirko / Meboldt, Mirko
en_US
ethz.leitzahl.certified
ETH Zürich::00002 - ETH Zürich::00012 - Lehre und Forschung::00007 - Departemente::02130 - Dep. Maschinenbau und Verfahrenstechnik / Dep. of Mechanical and Process Eng.::02665 - Inst. f. Design, Mat. und Fabrikation::03943 - Meboldt, Mirko / Meboldt, Mirko
en_US
ethz.date.deposited
2017-12-19T09:25:52Z
ethz.source
FORM
ethz.eth
yes
en_US
ethz.availability
Metadata only
en_US
ethz.rosetta.installDate
2018-06-01T05:59:43Z
ethz.rosetta.lastUpdated
2019-01-02T13:08:35Z
ethz.rosetta.versionExported
true
ethz.COinS
ctx_ver=Z39.88-2004&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.atitle=Investigation%20of%20the%20axial%20gap%20clearance%20in%20a%20hydrodynamically%20and%20passive%20magnetically%20levitated%20rotary%20blood%20pump%20using%20X-ray%20radio&rft.jtitle=Artificial%20Organs&rft.date=2018-05&rft.volume=42&rft.issue=5&rft.spage=510&rft.epage=515&rft.issn=1525-1594&0160-564X&rft.au=Thamsen,%20Bente&Plamondon,%20Mathieu&Granegger,%20Marcus&Schmid%20Daners,%20Marianne&Kaufmann,%20Rolf&rft.genre=article&
 Search via SFX

Files in this item

FilesSizeFormatOpen in viewer

There are no files associated with this item.

Publication type