dc.description.abstract
Background The aims of this study were to evaluate the construct validity (known group), concurrent validity (criterion based) and test-retest (intra-rater) reliability of manual goniometers to measure passive hip range of motion (ROM) in femoroacetabular impingement patients and healthy controls. Methods Passive hip flexion, abduction, adduction, internal and external rotation ROMs were simultaneously measured with a conventional goniometer and an electromagnetic tracking system (ETS) on two different testing sessions. A total of 15 patients and 15 sex- and age-matched healthy controls participated in the study. Results The goniometer provided greater hip ROM values compared to the ETS (range 2.0-18.9 degrees; P < 0.001); good concurrent validity was only achieved for hip abduction and internal rotation, with intraclass correlation coefficients (ICC) of 0.94 and 0.88, respectively. Both devices detected lower hip abduction ROM in patients compared to controls (P < 0.01). Test-retest reliability was good with ICCs higher 0.90, except for hip adduction (0.82-0.84). Reliability estimates did not differ between the goniometer and the ETS. Conclusions The present study suggests that goniometer-based assessments considerably overestimate hip joint ROM by measuring intersegmental angles (e.g., thigh flexion on trunk for hip flexion) rather than true hip ROM. It is likely that uncontrolled pelvic rotation and tilt due to difficulties in placing the goniometer properly and in performing the anatomically correct ROM contribute to the overrating of the arc of these motions. Nevertheless, conventional manual goniometers can be used with confidence for longitudinal assessments in the clinic.
en_US
dc.format
application/pdf
en_US
dc.language.iso
en
en_US
dc.publisher
BioMed Central
en_US
dc.rights.uri
http://creativecommons.org/licenses/by/2.0/
dc.subject
Intraclass Correlation Coefficient
en_US
dc.subject
Electromagnetic Tracking System
en_US
dc.subject
Manual Goniometer
en_US
dc.subject
High Intraclass Correlation Coefficient
en_US
dc.subject
Thigh Flexion
en_US
dc.title
Validity and test-retest reliability of manual goniometers for measuring passive hip range of motion in femoroacetabular impingement patients
en_US
dc.type
Journal Article
dc.rights.license
Creative Commons Attribution 2.0 Generic
dc.date.published
2010-08-31
ethz.journal.title
BMC Musculoskeletal Disorders
ethz.journal.volume
11
en_US
ethz.journal.abbreviated
BMC musculoskelet. disord. (Online)
ethz.pages.start
194
en_US
ethz.size
11 p.
en_US
ethz.version.deposit
publishedVersion
en_US
ethz.publication.place
London
en_US
ethz.publication.status
published
en_US
ethz.leitzahl
ETH Zürich::00002 - ETH Zürich::00012 - Lehre und Forschung::00007 - Departemente::02070 - Dep. Gesundheitswiss. und Technologie / Dep. of Health Sciences and Technology::02518 - Institut für Biomechanik / Institute for Biomechanics::03565 - Müller, Ralph / Müller, Ralph
en_US
ethz.leitzahl.certified
ETH Zürich::00002 - ETH Zürich::00012 - Lehre und Forschung::00007 - Departemente::02070 - Dep. Gesundheitswiss. und Technologie / Dep. of Health Sciences and Technology::02518 - Institut für Biomechanik / Institute for Biomechanics::03565 - Müller, Ralph / Müller, Ralph
ethz.date.deposited
2017-06-09T05:24:16Z
ethz.source
ECIT
ethz.identifier.importid
imp59364cfd0371199308
ethz.ecitpid
pub:37125
ethz.eth
yes
en_US
ethz.availability
Open access
en_US
ethz.rosetta.installDate
2017-07-15T06:14:04Z
ethz.rosetta.lastUpdated
2019-04-26T16:50:34Z
ethz.rosetta.exportRequired
true
ethz.rosetta.versionExported
true
ethz.COinS
ctx_ver=Z39.88-2004&amp;rft_val_fmt=info:ofi/fmt:kev:mtx:journal&amp;rft.atitle=Validity%20and%20test-retest%20reliability%20of%20manual%20goniometers%20for%20measuring%20passive%20hip%20range%20of%20motion%20in%20femoroacetabular%20impingement%20pa&amp;rft.jtitle=BMC%20Musculoskeletal%20Disorders&amp;rft.date=2010&amp;rft.volume=11&amp;rft.spage=194&amp;rft.issn=1471-2474&amp;rft.au=Nussbaumer,%20Silvio&amp;Leunig,%20Michael&amp;Glatthorn,%20Julia%20F.&amp;Stauffacher,%20Simone&amp;Gerber,%20Hans&amp;rft.genre=article&amp;
 Search via SFX

Files in this item

Thumbnail

Publication type

Show simple item record