Unconscious physiological response of healthy volunteers to dynamic respiration-synchronized couch motion
dc.contributor.author
Jöhl, Alexander
dc.contributor.author
Bogowicz, Marta
dc.contributor.author
Ehrbar, Stefanie
dc.contributor.author
Guckenberger, Matthias
dc.contributor.author
Klöck, Stephan
dc.contributor.author
Meboldt, Mirko
dc.contributor.author
Riesterer, Oliver
dc.contributor.author
Zeilinger, Melanie
dc.contributor.author
Schmid Daners, Marianne
dc.contributor.author
Tanadini-Lang, Stephanie
dc.date.accessioned
2018-02-16T12:54:57Z
dc.date.available
2018-02-16T12:54:19Z
dc.date.available
2018-02-16T12:54:57Z
dc.date.available
2017-11-29T08:09:17Z
dc.date.available
2017-11-29T09:08:56Z
dc.date.available
2017-11-30T07:07:40Z
dc.date.issued
2017-11-28
dc.identifier.other
10.1186/s13014-017-0925-6
en_US
dc.identifier.uri
http://hdl.handle.net/20.500.11850/242837
dc.identifier.doi
10.3929/ethz-b-000214927
dc.description.abstract
Background
Intrafractional motion can be a substantial uncertainty in precision radiotherapy. Conventionally, the target volume is expanded to account for the motion. Couch-tracking is an alternative, where the patient is moved to compensate for the tumor motion. However, the couch motion may influence the patient’s stress and respiration behavior decreasing the couch-tracking effectiveness.
Methods
In total, 100 volunteers were positioned supine on a robotic couch, which moved dynamically and respiration synchronized. During the measurement, the skin conductivity, the heartrate, and the gaze location were measured indicating the volunteer’s stress. Volunteers rated the subjective motion sickness using a questionnaire. The measurement alternated between static and tracking segments (three cycles), each 1 min long.
Results
The respiration amplitude showed no significant difference between tracking and static segments, but decreased significantly from the first to the last tracking segment (p < 0.0001). The respiration frequency differed significantly between tracking and static segments (p < 0.0001), but not between the first and the last tracking segment. The physiological parameters and the questionnaire showed mild signals of stress and motion sickness.
Conclusion
Generally, people tolerated the couch motions. The interaction between couch motion and the patient’s breathing pattern should be considered for a clinical implementation.
Trial registration
The study was registered at ClinicalTrials.gov (NCT02820532) and the Swiss national clinical trials portal (SNCTP000001878) on June 20, 2016.
en_US
dc.format
application/pdf
dc.language.iso
en
en_US
dc.publisher
BioMed Central
en_US
dc.rights.uri
http://creativecommons.org/licenses/by/4.0/
dc.subject
Tumor tracking
en_US
dc.subject
Robotic couch
en_US
dc.subject
Motion sickness
en_US
dc.subject
Respiration pattern
en_US
dc.title
Unconscious physiological response of healthy volunteers to dynamic respiration-synchronized couch motion
en_US
dc.type
Journal Article
dc.rights.license
Creative Commons Attribution 4.0 International
ethz.journal.title
Radiation Oncology
ethz.journal.volume
12
en_US
ethz.pages.start
189
en_US
ethz.size
7 p.
en_US
ethz.version.deposit
publishedVersion
en_US
ethz.identifier.wos
ethz.identifier.scopus
ethz.publication.status
published
en_US
ethz.leitzahl
ETH Zürich::00002 - ETH Zürich::00012 - Lehre und Forschung::00007 - Departemente::02130 - Dep. Maschinenbau und Verfahrenstechnik / Dep. of Mechanical and Process Eng.::02665 - Inst. f. Design, Mat. und Fabrikation / Inst. of Design, Materials a Fabrication::03943 - Meboldt, Mirko / Meboldt, Mirko
en_US
ethz.leitzahl
ETH Zürich::00002 - ETH Zürich::00012 - Lehre und Forschung::00007 - Departemente::02130 - Dep. Maschinenbau und Verfahrenstechnik / Dep. of Mechanical and Process Eng.::02619 - Inst. Dynam. Syst. u. Regelungstechnik / Inst. Dynamic Systems and Control::09563 - Zeilinger, Melanie / Zeilinger, Melanie
en_US
ethz.leitzahl.certified
ETH Zürich::00002 - ETH Zürich::00012 - Lehre und Forschung::00007 - Departemente::02130 - Dep. Maschinenbau und Verfahrenstechnik / Dep. of Mechanical and Process Eng.::02665 - Inst. f. Design, Mat. und Fabrikation / Inst. of Design, Materials a Fabrication::03943 - Meboldt, Mirko / Meboldt, Mirko
en_US
ethz.leitzahl.certified
ETH Zürich::00002 - ETH Zürich::00012 - Lehre und Forschung::00007 - Departemente::02130 - Dep. Maschinenbau und Verfahrenstechnik / Dep. of Mechanical and Process Eng.::02619 - Inst. Dynam. Syst. u. Regelungstechnik / Inst. Dynamic Systems and Control::09563 - Zeilinger, Melanie / Zeilinger, Melanie
en_US
ethz.date.deposited
2017-11-29T08:09:19Z
ethz.source
FORM
ethz.eth
yes
en_US
ethz.availability
Open access
en_US
ethz.rosetta.installDate
2018-02-21T14:19:56Z
ethz.rosetta.lastUpdated
2025-02-07T00:45:49Z
ethz.rosetta.exportRequired
true
ethz.rosetta.versionExported
true
dc.identifier.olduri
http://hdl.handle.net/20.500.11850/215437
dc.identifier.olduri
http://hdl.handle.net/20.500.11850/214927
ethz.COinS
ctx_ver=Z39.88-2004&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.atitle=Unconscious%20physiological%20response%20of%20healthy%20volunteers%20to%20dynamic%20respiration-synchronized%20couch%20motion&rft.jtitle=Radiation%20Oncology&rft.date=2017-11-28&rft.volume=12&rft.spage=189&rft.au=J%C3%B6hl,%20Alexander&Bogowicz,%20Marta&Ehrbar,%20Stefanie&Guckenberger,%20Matthias&Kl%C3%B6ck,%20Stephan&rft.genre=article&rft_id=info:doi/10.1186/s13014-017-0925-6&
Files in this item
Publication type
-
Journal Article [135803]