Show simple item record

dc.contributor.author
Koch, Stephan
dc.contributor.author
Soto Barcenas, Fernando
dc.contributor.author
Andersson, Göran
dc.date.accessioned
2021-07-28T12:46:23Z
dc.date.available
2017-06-09T06:49:16Z
dc.date.available
2018-09-13T10:07:03Z
dc.date.available
2021-07-28T12:46:23Z
dc.date.issued
2010
dc.identifier.issn
1474-6670
dc.identifier.other
10.3182/20100329-3-PT-3006.00048
en_US
dc.identifier.uri
http://hdl.handle.net/20.500.11850/25528
dc.description.abstract
This paper deals with the utilization of a large cluster of thermal household appliances, which are enabled to participate in active power control through a two-way communication system, for reducing the infeed prediction error of a wind generator. A recently developed coordination algorithm for thermostat-controlled appliances provides the basis for shaping the consumption profile of a multitude of dispersed heating and cooling devices. In the present approach, a Model Predictive Control strategy is used to operate the controllable thermal appliances together with a controllable generation unit in such a way that the financial penalties for external balancing are reduced.
en_US
dc.language.iso
en
en_US
dc.publisher
Elsevier
en_US
dc.subject
Wind
en_US
dc.subject
Forecasts
en_US
dc.subject
Electrical Appliances
en_US
dc.subject
Load Regulation
en_US
dc.subject
Predictive Control
en_US
dc.title
Using controllable thermal household appliances for wind forecast error reduction
en_US
dc.type
Conference Paper
dc.date.published
2016-04-23
ethz.book.title
1st IFAC Conference on Control Methodologies and Technology for Energy Efficiency
en_US
ethz.journal.title
IFAC Proceedings Volumes
ethz.journal.volume
43
en_US
ethz.journal.issue
1
en_US
ethz.pages.start
261
en_US
ethz.pages.end
266
en_US
ethz.event
1st IFAC Conference on Control Methodologies and Technology for Energy Efficiency (CMTEE 2010)
en_US
ethz.event.location
Vilamoura, Portugal
en_US
ethz.event.date
March 29-31, 2010
en_US
ethz.publication.place
Oxford
en_US
ethz.publication.status
published
en_US
ethz.leitzahl
ETH Zürich::00002 - ETH Zürich, direkt::00012 - Lehre und Forschung, direkt::00007 - Departemente, direkt::02140 - Departement Informationstechnologie und Elektrotechnik / Department of Information Technology and Electrical Engineering::02632 - Institut für Elektrische Energieübertragung und Hochspannungstechnik (EEH) / Power Systems and High Voltage Laboratory (EEH)::03559 - Andersson, Göran (emeritus)
en_US
ethz.leitzahl.certified
ETH Zürich::00002 - ETH Zürich, direkt::00012 - Lehre und Forschung, direkt::00007 - Departemente, direkt::02140 - Departement Informationstechnologie und Elektrotechnik / Department of Information Technology and Electrical Engineering::02632 - Institut für Elektrische Energieübertragung und Hochspannungstechnik (EEH) / Power Systems and High Voltage Laboratory (EEH)::03559 - Andersson, Göran (emeritus)
ethz.date.deposited
2017-06-09T06:49:36Z
ethz.source
ECIT
ethz.identifier.importid
imp59364d3a3ba2836406
ethz.ecitpid
pub:41286
ethz.eth
yes
en_US
ethz.availability
Metadata only
en_US
ethz.rosetta.installDate
2017-07-12T17:17:42Z
ethz.rosetta.lastUpdated
2018-09-13T10:07:05Z
ethz.rosetta.exportRequired
true
ethz.rosetta.versionExported
true
ethz.COinS
ctx_ver=Z39.88-2004&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.atitle=Using%20controllable%20thermal%20household%20appliances%20for%20wind%20forecast%20error%20reduction&rft.jtitle=IFAC%20Proceedings%20Volumes&rft.date=2010&rft.volume=43&rft.issue=1&rft.spage=261&rft.epage=266&rft.issn=1474-6670&rft.au=Koch,%20Stephan&Soto%20Barcenas,%20Fernando&Andersson,%20G%C3%B6ran&rft.genre=proceeding&rft_id=info:doi/10.3182/20100329-3-PT-3006.00048&rft.btitle=1st%20IFAC%20Conference%20on%20Control%20Methodologies%20and%20Technology%20for%20Energy%20Efficiency
 Search print copy at ETH Library

Files in this item

FilesSizeFormatOpen in viewer

There are no files associated with this item.

Publication type

Show simple item record