Show simple item record

dc.contributor.author
Wegmueller, Marc
dc.contributor.author
Lehner, Adrian
dc.contributor.author
Froehlich, Juerg
dc.contributor.author
Reutemann, Robert
dc.contributor.author
Oberle, Michael
dc.contributor.author
Felber, Norbert
dc.contributor.author
Kuster, Niels
dc.contributor.author
Hess, Otto
dc.contributor.author
Fichtner, Wolfgang
dc.date.accessioned
2020-09-10T12:51:33Z
dc.date.available
2017-06-09T11:02:49Z
dc.date.available
2020-09-10T12:51:33Z
dc.date.issued
2005
dc.identifier.isbn
0-7803-8740-6
en_US
dc.identifier.other
10.1109/IEMBS.2005.1617234
en_US
dc.identifier.uri
http://hdl.handle.net/20.500.11850/34902.1
dc.identifier.uri
http://hdl.handle.net/20.500.11850/34902
dc.description.abstract
Electronic data transfer by capacitive and galvanic coupling through the human body has been proposed by research and industry as a novel but highly promising technology for ultra low power wireless body LANs. Investigation on the most challenging questions considering data communication becomes enabled with a highly versatile measurement system for frequencies in the range of 10kHz to 1MHz. The human body is characterized as a transmission medium for electrical current by means of measurements and is investigated as communication channel for biomedical parameter monitoring by using different modulation schemes at low frequency. Excellent transmission was achieved on the thorax while the attenuation increases along the extremities. The injected current is 10 times below the maximum allowed contact current and more than 25 times below nerve stimulation. The new technology has shown its feasibility in clinical trials.
en_US
dc.language.iso
en
en_US
dc.publisher
IEEE
en_US
dc.title
Measurement System for the Characterization of the Human Body as a Communication Channel at Low Frequency
en_US
dc.type
Conference Paper
dc.date.published
2006-04-10
ethz.book.title
Proceedings of the 2005 IEEE Engineering in Medicine and Biology 27th Annual Conference
en_US
ethz.pages.start
3502
en_US
ethz.pages.end
3505
en_US
ethz.event
27th Annual International Conference of the Engineering in Medicine and Biology Society (IEEE-EMBS 2005)
en_US
ethz.event.location
Shanghai, China
en_US
ethz.event.date
September 1-4, 2005
en_US
ethz.identifier.wos
ethz.identifier.nebis
005216252
ethz.publication.place
Piscataway, NJ
en_US
ethz.publication.status
published
en_US
ethz.leitzahl
03228 - Fichtner, Wolfgang
en_US
ethz.leitzahl.certified
03228 - Fichtner, Wolfgang
ethz.date.deposited
2017-06-09T11:02:59Z
ethz.source
ECIT
ethz.identifier.importid
imp59364e07a7cf639652
ethz.ecitpid
pub:56122
ethz.eth
yes
en_US
ethz.availability
Metadata only
en_US
ethz.rosetta.installDate
2017-07-13T07:49:27Z
ethz.rosetta.lastUpdated
2021-02-15T17:08:50Z
ethz.rosetta.versionExported
true
ethz.COinS
ctx_ver=Z39.88-2004&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.atitle=Measurement%20System%20for%20the%20Characterization%20of%20the%20Human%20Body%20as%20a%20Communication%20Channel%20at%20Low%20Frequency&rft.date=2005&rft.spage=3502&rft.epage=3505&rft.au=Wegmueller,%20Marc&Lehner,%20Adrian&Froehlich,%20Juerg&Reutemann,%20Robert&Oberle,%20Michael&rft.isbn=0-7803-8740-6&rft.genre=proceeding&rft_id=info:doi/10.1109/IEMBS.2005.1617234&rft.btitle=Proceedings%20of%20the%202005%20IEEE%20Engineering%20in%20Medicine%20and%20Biology%2027th%20Annual%20Conference
 Search print copy at ETH Library

Files in this item

FilesSizeFormatOpen in viewer

There are no files associated with this item.