Study and parameter optimization of a tuning method for the online calibration of the RD53A readout chip
Abstract
The RD53A is a prototype of the readout chip that will be used in the Compact Muon Solenoid (CMS) pixel detector after the High-Lumi LHC (HL-LHC) upgrade is complete beyond 2025. A new feature of the chip enables the writing of configuration commands between triggers during operation. This feature can be used to compensate for a detuning of the pixels due to radiation damage or temperature fluctuations over time. This paper studies the efficiency of such a method as well as its side-effects and the dependency on its parameters using an equivalent software implementation. Show more