CG‐SENSE revisited: Results from the first ISMRM reproducibility challenge
dc.contributor.author
Maier, Oliver
dc.contributor.author
Baete, Steven H.
dc.contributor.author
Fyrdahl, Alexander
dc.contributor.author
Hammernik, Kerstin
dc.contributor.author
Harrevelt, Seb
dc.contributor.author
Kasper, Lars
dc.contributor.author
Karakuzu, Agah
dc.contributor.author
Loecher, Michael
dc.contributor.author
Patzig, Franz
dc.contributor.author
Tian, Ye
dc.contributor.author
Wang, Ke
dc.contributor.author
Gallichan, Daniel
dc.contributor.author
Uecker, Martin
dc.contributor.author
Knoll, Florian
dc.date.accessioned
2021-03-02T08:10:37Z
dc.date.available
2020-11-25T03:53:36Z
dc.date.available
2020-11-30T11:43:29Z
dc.date.available
2021-03-02T08:10:37Z
dc.date.issued
2021-04
dc.identifier.issn
0740-3194
dc.identifier.issn
1522-2594
dc.identifier.other
10.1002/mrm.28569
en_US
dc.identifier.uri
http://hdl.handle.net/20.500.11850/452883
dc.description.abstract
Purpose The aim of this work is to shed light on the issue of reproducibility in MR image reconstruction in the context of a challenge. Participants had to recreate the results of "Advances in sensitivity encoding with arbitrary k-space trajectories" by Pruessmann et al. Methods The task of the challenge was to reconstruct radially acquired multicoil k-space data (brain/heart) following the method in the original paper, reproducing its key figures. Results were compared to consolidated reference implementations created after the challenge, accounting for the two most common programming languages used in the submissions (Matlab/Python). Results Visually, differences between submissions were small. Pixel-wise differences originated from image orientation, assumed field-of-view, or resolution. The reference implementations were in good agreement, both visually and in terms of image similarity metrics. Discussion and Conclusion While the description level of the published algorithm enabled participants to reproduce CG-SENSE in general, details of the implementation varied, for example, density compensation or Tikhonov regularization. Implicit assumptions about the data lead to further differences, emphasizing the importance of sufficient metadata accompanying open datasets. Defining reproducibility quantitatively turned out to be nontrivial for this image reconstruction challenge, in the absence of ground-truth results. Typical similarity measures like NMSE of SSIM were misled by image intensity scaling and outlier pixels. Thus, to facilitate reproducibility, researchers are encouraged to publish code and data alongside the original paper. Future methodological papers on MR image reconstruction might benefit from the consolidated reference implementations of CG-SENSE presented here, as a benchmark for methods comparison.
en_US
dc.language.iso
en
en_US
dc.publisher
Wiley
en_US
dc.subject
CG‐SENSE
en_US
dc.subject
image reconstruction
en_US
dc.subject
MRI
en_US
dc.subject
nonuniform sampling
en_US
dc.subject
NUFFT
en_US
dc.subject
reproducibility
en_US
dc.title
CG‐SENSE revisited: Results from the first ISMRM reproducibility challenge
en_US
dc.type
Review Article
dc.date.published
2020-11-12
ethz.journal.title
Magnetic Resonance in Medicine
ethz.journal.volume
85
en_US
ethz.journal.issue
4
en_US
ethz.journal.abbreviated
Magn Reson Med
ethz.pages.start
1821
en_US
ethz.pages.end
1839
en_US
ethz.identifier.wos
ethz.identifier.scopus
ethz.publication.place
Hoboken, NJ
en_US
ethz.publication.status
published
en_US
ethz.leitzahl
ETH Zürich::00002 - ETH Zürich::00012 - Lehre und Forschung::00007 - Departemente::02140 - Dep. Inf.technologie und Elektrotechnik / Dep. of Inform.Technol. Electrical Eng.::02631 - Institut für Biomedizinische Technik / Institute for Biomedical Engineering::03955 - Stephan, Klaas E. / Stephan, Klaas E.
en_US
ethz.leitzahl
ETH Zürich::00002 - ETH Zürich::00012 - Lehre und Forschung::00007 - Departemente::02140 - Dep. Inf.technologie und Elektrotechnik / Dep. of Inform.Technol. Electrical Eng.::02631 - Institut für Biomedizinische Technik / Institute for Biomedical Engineering::03628 - Prüssmann, Klaas P. / Prüssmann, Klaas P.
en_US
ethz.date.deposited
2020-11-25T03:53:45Z
ethz.source
WOS
ethz.eth
yes
en_US
ethz.availability
Metadata only
en_US
ethz.rosetta.installDate
2021-03-02T08:10:48Z
ethz.rosetta.lastUpdated
2021-03-02T08:10:48Z
ethz.rosetta.versionExported
true
ethz.COinS
ctx_ver=Z39.88-2004&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.atitle=CG%E2%80%90SENSE%20revisited:%20Results%20from%20the%20first%20ISMRM%20reproducibility%20challenge&rft.jtitle=Magnetic%20Resonance%20in%20Medicine&rft.date=2021-04&rft.volume=85&rft.issue=4&rft.spage=1821&rft.epage=1839&rft.issn=0740-3194&1522-2594&rft.au=Maier,%20Oliver&Baete,%20Steven%20H.&Fyrdahl,%20Alexander&Hammernik,%20Kerstin&Harrevelt,%20Seb&rft.genre=article&rft_id=info:doi/10.1002/mrm.28569&
Files in this item
Files | Size | Format | Open in viewer |
---|---|---|---|
There are no files associated with this item. |
Publication type
-
Review Article [4116]