Initial experience with the new type A arch dissection stent: restoration of supra-aortic vessel perfusion
dc.contributor.author
Montagner, Matteo
dc.contributor.author
Kofler, Markus
dc.contributor.author
Heck, Roland
dc.contributor.author
Buz, Semih
dc.contributor.author
Starck, Christoph
dc.contributor.author
Kurz, Stephan
dc.contributor.author
Falk, Volkmar
dc.contributor.author
Kempfert, Jörg
dc.date.accessioned
2021-09-03T14:26:05Z
dc.date.available
2021-08-18T02:47:22Z
dc.date.available
2021-09-03T14:21:28Z
dc.date.available
2021-09-03T14:26:05Z
dc.date.issued
2021-08
dc.identifier.issn
1569-9293
dc.identifier.issn
1569-9285
dc.identifier.other
10.1093/icvts/ivab085
en_US
dc.identifier.uri
http://hdl.handle.net/20.500.11850/501221
dc.description.abstract
OBJECTIVES
The goal of the present study is to investigate changes in supra-aortic vessel perfusion after implantation of the non-covered Ascyrus Medical Dissection Stent (AMDS) for surgical treatment of acute type A aortic dissection.
METHODS
From 2017 to 2020, 16 consecutive patients treated with AMDS and involvement (dissection to total occlusion) of at least 1 supra-aortic vessel were included in the study. Centre-line based computed tomography measurements of true, false and total lumen area using Terarecon software were performed before and after surgery. Changes in the true lumen area were indexed to the entire vessel area. The paired sample t-test was used to assess the significance of the observed differences.
RESULTS
Analysis of supra-aortic vessels and the descending aorta showed significant improvement in true lumen perfusion after the AMDS was implanted. The indexed true lumen area increased postoperatively by 72%, 112% and 30% in the innominate, right and left common carotid arteries, respectively. Total occlusions of both common carotid arteries recovered completely after surgical treatment. The proximal- and the mid-descending aorta showed a 78% and 48% improvement of the indexed true lumen area, respectively.
CONCLUSIONS
Arch repair using AMDS shows promising results in the treatment of acute type A aortic dissection. Quantitative measurements of true and false lumen perfusion demonstrated a significant increase in true lumen area and a 100% regression of totally occluded supra-aortic branches. Further examination in a larger cohort of patients and comparison with isolated hemiarch repair are needed to confirm positive vascular remodelling after an AMDS implant.
en_US
dc.language.iso
en
en_US
dc.publisher
Oxford University Press
en_US
dc.subject
Type A aortic dissection
en_US
dc.subject
Arch repair
en_US
dc.subject
Cerebral malperfusion
en_US
dc.subject
DeBakey I
en_US
dc.subject
Ascyrus Medical Dissection Stent
en_US
dc.title
Initial experience with the new type A arch dissection stent: restoration of supra-aortic vessel perfusion
en_US
dc.type
Conference Paper
dc.date.published
2021-05-19
ethz.journal.title
Interactive Cardiovascular and Thoracic Surgery
ethz.journal.volume
33
en_US
ethz.journal.issue
2
en_US
ethz.journal.abbreviated
Interact Cardiovasc Thorac Surg
ethz.pages.start
276
en_US
ethz.pages.end
283
en_US
ethz.event
34th Annual Meeting of the European Association for Cardio-Thoracic Surgery
en_US
ethz.event.location
Barcelona, Spain
en_US
ethz.event.date
October 8-10, 2020
en_US
ethz.identifier.wos
ethz.identifier.scopus
ethz.publication.place
Oxford
en_US
ethz.publication.status
published
en_US
ethz.leitzahl
ETH Zürich::00002 - ETH Zürich::00012 - Lehre und Forschung::00007 - Departemente::02070 - Dep. Gesundheitswiss. und Technologie / Dep. of Health Sciences and Technology::02540 - Institut für Translationale Medizin / Institute of Translational Medicine::09667 - Falk, Volkmar / Falk, Volkmar
ethz.leitzahl.certified
ETH Zürich::00002 - ETH Zürich::00012 - Lehre und Forschung::00007 - Departemente::02070 - Dep. Gesundheitswiss. und Technologie / Dep. of Health Sciences and Technology::02540 - Institut für Translationale Medizin / Institute of Translational Medicine::09667 - Falk, Volkmar / Falk, Volkmar
ethz.date.deposited
2021-08-18T02:47:26Z
ethz.source
SCOPUS
ethz.eth
yes
en_US
ethz.availability
Metadata only
en_US
ethz.rosetta.installDate
2021-09-03T14:26:12Z
ethz.rosetta.lastUpdated
2022-03-29T11:29:23Z
ethz.rosetta.versionExported
true
ethz.COinS
ctx_ver=Z39.88-2004&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.atitle=Initial%20experience%20with%20the%20new%20type%20A%20arch%20dissection%20stent:%20restoration%20of%20supra-aortic%20vessel%20perfusion&rft.jtitle=Interactive%20Cardiovascular%20and%20Thoracic%20Surgery&rft.date=2021-08&rft.volume=33&rft.issue=2&rft.spage=276&rft.epage=283&rft.issn=1569-9293&1569-9285&rft.au=Montagner,%20Matteo&Kofler,%20Markus&Heck,%20Roland&Buz,%20Semih&Starck,%20Christoph&rft.genre=proceeding&rft_id=info:doi/10.1093/icvts/ivab085&
Files in this item
Files | Size | Format | Open in viewer |
---|---|---|---|
There are no files associated with this item. |
Publication type
-
Conference Paper [35328]