Metadata only
Date
2007Type
- Conference Paper
ETH Bibliography
yes
Altmetrics
Abstract
Pulsed power systems often use a pulse transformer to generate high voltage pulses. In order to improve the utilization of the transformer core material usually a dc reset circuit is applied which results in a smaller transformer volume. However, by the use of a reset circuit additional losses are genrated. Usually, in the dimensioning of the reset circuit only the copper losses are considered but these are only a small part of the whole losses. In this paper analytical equations for calculating the losses in the pulsed power system and a method for optimizing a dc reset circuit are presented. With the optimization method a reset circuit for an existing system is designed and the results are validated by simulation and by measurements. Show more
Publication status
publishedExternal links
Book title
APEC 07 - Twenty-Second Annual IEEE Applied Power Electronics Conference and ExpositionPages / Article No.
Publisher
IEEEEvent
Organisational unit
03573 - Kolar, Johann W. / Kolar, Johann W.
More
Show all metadata
ETH Bibliography
yes
Altmetrics