dc.description.abstract
In this work we investigate the validity of the following assumptions that were used in previous studies of the endolymph motion within the semicircular canals of the inner ear: (a) quasi-steadiness and therefore exclusion of the time derivative, (b) absence of advection, (c) insignicance of Coriolis and centrifugal forces. A parameter study is performed using the C++ based OpenFOAM® software library for nu- merical simulations on a nite volume grid. For validation purposes, the solutions are compared with results from the method of fundamental solutions to compute the ow in a quasi-steady Stokes flow regime. We conclude that the assumptions are valid for a standard head maneuver.
en_US
dc.format
application/pdf
dc.language.iso
en
en_US
dc.publisher
Institute of Fluid Dynamics, Eidgenössische Technische Hochschule Zürich
en_US
dc.rights.uri
http://creativecommons.org/licenses/by-nd/3.0/
dc.subject
LABYRINTH + GLEICHGEWICHTSORGANE (ANATOMIE UND PHYSIOLOGIE)
en_US
dc.subject
MODELLRECHNUNG UND SIMULATION IN DER PHYSIOLOGIE
en_US
dc.subject
MATHEMATICAL MODELING AND SIMULATION IN PHYSIOLOGY
en_US
dc.subject
LABYRINTH + EQUILIBRIUM ORGANS (ANATOMY AND PHYSIOLOGY)
en_US
dc.title
Validation of assumptions on the endolymph motion inside the semicircular canals of the inner ear
en_US
dc.type
Report
dc.rights.license
Creative Commons Attribution-NoDerivs 3.0 Unported
dc.date.published
2012
ethz.journal.title
Internal Reports of the Institute of Fluid Dynamics, ETH Zurich
ethz.size
15 p.
en_US
ethz.code.ddc
DDC - DDC::6 - Technology, medicine and applied sciences::610 - Medical sciences, medicine
en_US
ethz.identifier.nebis
007588055
ethz.publication.place
Zürich
en_US
ethz.publication.status
published
en_US
ethz.leitzahl
ETH Zürich::00002 - ETH Zürich::00012 - Lehre und Forschung::00007 - Departemente::02130 - Dep. Maschinenbau und Verfahrenstechnik / Dep. of Mechanical and Process Eng.::02628 - Institut für Fluiddynamik / Institute of Fluid Dynamics
en_US
ethz.leitzahl
03419 - Kleiser, Leonhard
en_US
ethz.leitzahl.certified
03419 - Kleiser, Leonhard
ethz.date.deposited
2017-06-10T15:29:36Z
ethz.source
ECOL
ethz.source
ECIT
ethz.identifier.importid
imp593650784306e65292
ethz.identifier.importid
imp59366b339f63747835
ethz.ecolpid
eth:6367
ethz.ecitpid
pub:103801
ethz.eth
yes
en_US
ethz.availability
Open access
en_US
ethz.rosetta.installDate
2017-07-04T11:49:14Z
ethz.rosetta.lastUpdated
2019-02-02T16:08:37Z
ethz.rosetta.exportRequired
true
ethz.rosetta.versionExported
true
ethz.COinS
ctx_ver=Z39.88-2004&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.atitle=Validation%20of%20assumptions%20on%20the%20endolymph%20motion%20inside%20the%20semicircular%20canals%20of%20the%20inner%20ear&rft.jtitle=Internal%20Reports%20of%20the%20Institute%20of%20Fluid%20Dynamics,%20ETH%20Zurich&rft.date=2012&rft.au=Grieser,%20Bernhard&Obrist,%20Dominik&Kleiser,%20Leonhard&rft.genre=report&
 Search via SFX

Files in this item

Thumbnail

Publication type

Show simple item record