Erosion of Pelton buckets and changes in turbine efficiency measured in the HPP Fieschertal
(2016)IOP Conference Series: Earth and Environmental ScienceGeometrical changes and material loss of Pelton turbine runners as well as changes in turbine efficiency were measured at HPP Fieschertal in Valais, Switzerland. The HPP is equipped with two horizontal axis Pelton units, with each 32 MW nominal power, 7.5 m3/s design discharge, 515 m head and two injectors. The injectors and the buckets are hard-coated. Hydro-abrasive erosion was quantified based on repeated measurements on two runner ...Conference Paper