Kurzer Serviceunterbruch am Donnerstag, 22. Januar 2026, 12 bis 13 Uhr. Sie können in diesem Zeitraum keine neuen Dokumente hochladen oder bestehende Einträge bearbeiten. Das Login wird in diesem Zeitraum deaktiviert. Grund: Wartungsarbeiten // Short service interruption on Thursday, January 22, 2026, 12.00 – 13.00. During this time, you won’t be able to upload new documents or edit existing records. The login will be deactivated during this time. Reason: maintenance work
 

Does Size Matter for Female Continuous-flow LVAD Recipients? A Translational Approach to a Decade Long Question


METADATA ONLY
Loading...

Date

2022-01

Publication Type

Journal Article

ETH Bibliography

yes

Citations

Altmetric
METADATA ONLY

Data

Rights / License

Abstract

Females have increased risk of right-ventricular failure (RVF) and 3 month mortality after left-ventricular assist device (LVAD) implantation. In this translational study, we tested the hypothesis that sex differences in outcomes are driven by pump-induced LV size-volume mismatch, due to a negative impact on interventricular septal (IVS) interdependence. Adult continuous-flow LVAD recipients from the International Society For Heart And Lung Transplantation Mechanically Assisted Circulatory Support registry (n = 15,498) were studied to determine association of female sex with outcomes of 3 month mortality and RVF. Female sex was associated with smaller preimplant left-ventricular end-diastolic diameter (6.5 vs. 6.9 cm, p < 0.001), increased 3 month mortality (odds ratio [OR]: 1.42, p < 0.001) and RVF (OR: 1.18, p = 0.005). Smaller left-ventricular end-diastolic diameter was associated with worse outcomes after LVAD implantation (OR for mortality: 1.20, p < 0.001; RVF: 1.09, p < 0.001), and attenuated the association of female sex with these outcomes. In test bench heart phantoms (n = 4), the IVSs of smaller hearts demonstrated abnormal leftward shift earlier than larger hearts (volume change at IVS shift: 40 [95% confidence interval: 30–52] vs. 50 [95% confidence interval: 48–69] ml). Smaller LV size partially mediates worse post-LVAD outcomes for female patients, due to lower volume thresholds for adverse IVS shifting.

Publication status

published

Editor

Book title

Journal / series

Volume

68 (1)

Pages / Article No.

21 - 27

Publisher

Lippincott Williams & Wilkins

Event

Edition / version

Methods

Software

Geographic location

Date collected

Date created

Subject

left ventricular assist device; sex differences; mortality; right ventricular failure