Risk-Based Evaluation of the Microbial Water Quality in On-Site Non-Potable Water Reuse Systems


Author / Creator

Date

2024

Publication Type

Doctoral Thesis

ETH Bibliography

yes

Citations

Altmetric

Data

Abstract

The availability of sufficient quantities of clean water is essential for human health and well-being. Unfortunately, freshwater is becoming increasingly scarce. On-site water reuse, e.g., at the scale of a household or a building, offers an opportunity to provide reliable quantities of water for non-potable applications without the need for centralized large-scale infrastructure to collect the wastewater or distribute the reclaimed water. However, the widespread implementation of on-site water reuse systems is currently impeded by the limited ability to ensure the level of treatment and protection of human health during operation. The aim of this PhD thesis was to advance knowledge on the design, operation and monitoring of on-site non-potable water reuse systems. The thesis revolves around three main objectives: (1) defining pathogen removal targets for on-site water reuse systems; (2) optimizing the operation of on-site water reuse systems in order to achieve these targets; and (3) establishing risk-based approaches to monitor that targets are met during operation. Chapter 1 introduces the rationales driving the growing interest in on-site water reuse and highlights current challenges around microbial risk assessment, on-site technologies for, and monitoring of on-site water reuse systems. Chapter 2 analyzes the applicability of current water reuse frameworks (regulations, guidelines, etc.) for novel on-site water reuse systems. The study finds that publications on novel small-scale water reuse technologies frequently misinterpret quality targets from such frameworks, presumably because the frameworks are not fully applicable to small-scale water reuse systems. Emphasis is placed on the need for water reuse frameworks to co-evolve with emerging small-scale technologies. In particular, updated frameworks will need to: (1) provide treatment targets for novel applications of reclaimed water (e.g., high-quality applications such as handwashing or showering); and (2) provide guidance for remote monitoring possibilities for on-site systems, where traditional manual sampling and laboratory analysis are economically no longer feasible. The subsequent chapters aim to address these two knowledge gaps. Chapter 3 employs quantitative microbial risk assessment to establish pathogen log-removal targets for the recycling of greywater that will limit the risk to human health to an acceptable benchmark. The study considers three greywater collection scales (5, 100, or 1’000 people), and seven reuse scenarios, including recycling of water for laundry, toilet flushing, showering, and handwashing. Reducing the collection scale to 5 people leads to a decrease in the 95% quantile of log-removal targets to 0 for most reference pathogens. However, removal targets for norovirus, the most prevalent pathogen, are high even at this small collection scale, negating any advantages in terms of treatment requirements. Similarly, the study reveals that log-removal targets vary considerably depending on the reuse application. However, in most cases, similar treatment trains are required to meet the targets, reducing the benefit that lower treatment targets could have in terms of costs and environmental impact. Notable exceptions are water recycling washing machines and handwashing stations, for which simpler treatment is sufficient. Chapter 4 proposes a methodology to link measurements from commercially available online sensors to risk-based water quality targets, providing operation setpoints protective of human health for specific combinations of wastewaters and reuse applications. In two laboratory-operated water reuse systems (membrane bioreactors with chlorination), the oxidation-reduction potential and free chlorine sensors are closely related to the microbial water quality (virus removal, regrowth of bacteria in the treated water). This is not the case for turbidity, UV absorbance at 254 nm, and conductivity. Using a mechanism-based model to link sensor measurements and microbial water quality parameters (virus removal and bacterial regrowth), sensor setpoints for the oxidation-reduction potential and free chlorine are established. These sensor setpoints can be used to tune on-site water reuse system to specific reuse applications by ensuring that the corresponding microbial treatment targets are met in normal operation. Such a systematic approach to setting sensor setpoints could be used in the development of water reuse guidelines and regulations that aim to cover a range of reuse applications with differential risks to human health. In Chapter 5, the same set of sensors is used in combination with machine learning approaches for real-time prediction of the microbial water quality, e.g., during failures of system components. The assumption underlying the development of the prediction model is that the percentage of safe predictions, which are predictions indicating that water quality meets treatment targets, when the actual condition is unsafe must be minimized. This is essential to protect user health. The optimization of the overall prediction accuracy is given second priority. Our results show that logistic-regression-based models using only two out of the six sensors (free chlorine and oxidation-reduction potential) achieve the highest prediction accuracy. Analysis of the occurrence of false predictions shows that these are mostly early alarms, a characteristic that could be regarded as an asset in alarm management. Overall, the study shows that for microbial water quality predictions, which rely on inherently limited training and validation datasets, simple prediction models using only a few sensors perform as well as or even better than more complex black-box models or models using inputs from multiple sensors. For Chapter 6, we move from the laboratory to the field and study two implemented building-scale water reuse plants in Bengaluru, India, where the reclaimed water is used for toilet flushing and landscaping. A sampling campaign reveals that the microbial quality of the reclaimed water is highly variable, with frequent instances during which the water is not suitable for reuse. The variability in microbial water quality results from ineffective chlorination, caused by: (1) fluctuations of the chlorine demand of the water; and (2) the low frequency of chlorination (once to twice per day). The results highlight the value of establishing operational setpoints for the automation of chlorination as a strategy to manage the variable chlorine demand of the water. Overall, the findings from this PhD thesis emphasize that design, operation and monitoring of on-site water reuse systems are closely related, and must be considered jointly. The research works included in this thesis offer practical recommendations for establishing risk-based treatment targets, along with guidance on deploying sensors for the operation of on-site systems and monitoring of the reclaimed water quality. These insights are relevant for regulators as well as developers and operators of on-site water reuse systems.

Publication status

published

Editor

Book title

Journal / series

Volume

Pages / Article No.

Publisher

ETH Zurich

Event

Edition / version

Methods

Geographic location

Date collected

Date created

Subject

Organisational unit

03832 - Morgenroth, Eberhard / Morgenroth, Eberhard check_circle

Notes

Funding Info about funding

Related publications and datasets