Andreas Ritter
Loading...
10 results
Filters
Reset filtersSearch Results
Publications 1 - 10 of 10
- Five Years of Pulsed Current Testing for HVDC SwitchgearItem type: Conference Paper
2016 IEEE International Conference on High Voltage Engineering and Application (ICHVE)Ritter, Andreas; Bort, Lorenz; Franck, Christian (2016) - Alternative Testmethode von TrennschalternItem type: Other Conference ItemRitter, Andreas; Straumann, U.; Riechert, U.; et al. (2014)
- Prediction of Bus-Transfer Switching in Future HVDC SubstationsItem type: Journal Article
IEEE Transactions on Power DeliveryRitter, Andreas; Franck, Christian (2018) - Improved Frequency Bias Factor Sizing for Non-Interactive ControlItem type: Other Conference ItemScherer, Marc; Iggland, Emil; Ritter, Andreas; et al. (2012)
- Improving GIS Disconnectors for Future HVDC ApplicationsItem type: Journal Article
IEEE Transactions on Power DeliveryRitter, Andreas; Straumann, Ueli; Franck, Christian (2019)The use of standard HVac disconnectors for bus-transfer switching in future HVdc gas insulated switchgear (GIS) has been demonstrated successfully in past research through simulation and testing. Prolonged arcing times through reignitions caused by high frequency harmonics as well as the proposed extension of GIS disconnector switching cases, however, create an HVdc-specific demand for more advanced disconnector concepts capable of withstanding higher switching stresses and increased recovery voltages. A spring-loaded disconnector designed for use in HVac mixed technology switchgear (MTS) was found to shorten the time to first current zero through an accelerated increase of the arcing voltage compared to standard disconnectors. Despite its increased switching performance, the reignition characteristics of this fast-acting disconnector were found to largely follow the previously established extinction criterion, which enables further simulation of similar technologies for HVdc applications. To additionally combat the issue of contamination of HVdc GIS by electrode erosion products, a prototype disconnector was improved using permanent magnets to evoke arc rotation. Erosion tests in air have shown an effective reduction of electrode erosion for long arcing times at currents typical for disconnector switching while bus-transfer tests revealed promising enhancements of the reignition behavior. - Novel Method for Predicting Limit Performance of Bus-Transfer Switching by DisconnectorsItem type: Journal Article
IEEE Transactions on Power DeliveryRitter, Andreas; Straumann, Ueli; Franck, Christian (2017) - Disconnector Switching in HVAC and Future HVDC GISItem type: Doctoral ThesisRitter, Andreas (2018)
- Investigation of LC-Resonance Driving in Disconnector Bus-Transfer TestingItem type: Conference PaperRitter, Andreas; Straumann, Ulrich; Riechert, Uwe; et al. (2014)
- Analysis Method and Implications of Utilizing a Full Bus-Transfer Setup for Testing DisconnectorsItem type: Conference PaperRitter, Andreas; Straumann, Ulrich; Riechert, Uwe; et al. (2015)
- Derivation of requirements for small-current switching in future HVDC substationsItem type: Conference Paper
18th International Symposium on High Voltage EngineeringRitter, Andreas; Walter, Michael M.; Straumann, Ulrich; et al. (2013)
Publications 1 - 10 of 10