Improving proton therapy delivery efficiency via combination of advanced spot positioning algorithms and ridge filter


METADATA ONLY
Loading...

Date

2023

Publication Type

Other Conference Item

ETH Bibliography

yes

Citations

Altmetric
METADATA ONLY

Data

Rights / License

Abstract

Purpose: Rescanning, gating, and breath-hold are promising approaches for realising proton therapy treatments of moving targets, but decrease delivery efficiency, lengthening treatment delivery time. In PBS (Pencil Beam Scanning) proton therapy, two factors influence the treatment delivery time: the beam-on time and the dead time, which is the time required for energy-layer and spot-position adjustments. Several studies demonstrated that ridge filters (RFs) effectively decrease the dead time by reducing the number of energy layers and therefore of spots. Further, the use of different spot placement techniques can reduce dead time by minimizing the number of spots required. However, clinics use different spot placements, with no consensus on the optimal one, and RFs are not employed clinically in PBS proton therapy. In this study, we examined the advantages and limitations of combining a RF with various spot placement techniques to reduce the delivery time without compromising the plan quality, to pave the way for a future clinical implementation. Methods: We created treatment plans on a cohort of 12 different patients affected by lung tumors using a RF that broadens the Bragg peak into a Gaussian shape, in combination with a fixed grid-based spot placement technique (FG configuration), an energy-dependent technique based on the beam’s size in air (A configuration) and an energy-dependent technique based on the beam’s size in water (W configuration) and compared configuration performances in terms of plan quality and clinical acceptability. Results: Results indicated that FG plans showed the best performance. The A and W plans, instead, performed poorly, with W plans providing the worst results and not yielding any acceptable plans due the treatment planning system being constrained by a limited number of degrees of freedom. Conclusion: In conclusion, we found that by combining the RF with a spot placement algorithm based on a fixed grid, we can obtain treatment plans with a good clinical outcome and significantly reduce the delivery time, improving the overall quality of the treatment, thus potentially increasing 4D treatments feasibility.

Publication status

published

Editor

Book title

56th SSRMP Annual Meeting. Booklet

Journal / series

Volume

Pages / Article No.

30 - 30

Publisher

Swiss Society of Radiobiology and Medical Physics

Event

56th SSRMP Annual Meeting

Edition / version

Methods

Software

Geographic location

Date collected

Date created

Subject

Proton therapy; Breath-hold; PBS proton therapy; NSCLC

Organisational unit

01453 - MSc Physik / MSc Physics

Notes

Conference lecture held on December 1, 2023

Funding

Related publications and datasets