A Modified Direct Power Control Strategy Allowing the Connection of Three-Phase Inverters to the Grid Through LCL Filters


METADATA ONLY
Loading...

Date

2007

Publication Type

Journal Article

ETH Bibliography

yes

Citations

Altmetric
METADATA ONLY

Data

Rights / License

Abstract

This paper proposes a novel approach to adapt a conventional direct power control (DPC) for high-power applications, where a third-order LCL filter is frequently required. The LCL filter can cause a strong resonance and requires additional effort for system control. The application of a DPC for the control of a three-phase voltage source inverter that is connected to the grid through an filter has not yet been considered. The addition of an active damping strategy, together with a harmonic rejection control loop, to the conventional DPC is proposed and analyzed in this paper. The steady-state, as well as the dynamic performance of the proposed system, is verified with simulation results and experimental measurements.

Publication status

published

Editor

Book title

Volume

43 (5)

Pages / Article No.

1388 - 1400

Publisher

IEEE

Event

Edition / version

Methods

Software

Geographic location

Date collected

Date created

Subject

$LCL$ filter; Active damping; direct power control (DPC); grid-connected inverter

Organisational unit

03573 - Kolar, Johann W. (emeritus) / Kolar, Johann W. (emeritus) check_circle

Notes

Funding

Related publications and datasets

Is new version of: