Experimental determination of the extinction coefficient for a packed-bed particulate medium


METADATA ONLY
Loading...

Date

2006-01

Publication Type

Journal Article

ETH Bibliography

yes

Citations

Altmetric
METADATA ONLY

Data

Rights / License

Abstract

The extinction coefficient of a powder mixture of ZnO and beech charcoal is determined at ambient temperature using two experimental set-ups: (a) radiation in the range 500-1000 nm is captured by a 200 m-diameter fiber optic and sent to a spectrometer equipped with a Si/PbSe detector; (b) radiation in the range 350-1100 nm is captured by a 5 mm-diameter Si-photodiode. Both set-ups measure the attenuation of intensity from a 3273 K blackbody source. The experimental results are implemented in the numerical solution of the equation of radiative transfer, using the Monte-Carlo ray-tracing technique. The extinction coefficient is determined to be 10103 615 m⁻¹ at 1000 nm using set up (a), and 7850 337 m⁻¹ for the range 350-1100 nm using the more accurate set-up (b).

Publication status

published

Editor

Book title

Volume

19 (1)

Pages / Article No.

69 - 79

Publisher

Taylor & Francis

Event

Edition / version

Methods

Geographic location

Date collected

Date created

Subject

Thermal radiation; Extinction coefficient; Monte Carlo; Porous media; Packed bed

Organisational unit

03530 - Steinfeld, Aldo (emeritus) / Steinfeld, Aldo (emeritus) check_circle

Notes

Received 15 April 2005, Accepted 15 June 2005, Published online 20 Aug 2006.

Funding Info about funding