Journal: Bioengineering
Loading...
Abbreviation
Publisher
MDPI
22 results
Search Results
Publications 1 - 10 of 22
- The Bistable Behaviour of Pseudomonas putida KT2440 during PHA Depolymerization under Carbon LimitationItem type: Journal Article
BioengineeringKarmann, Stephanie; Panke, Sven; Zinn, Manfred (2017)Poly(hydroxyalkanoates) (PHAs) are bacterial polyesters offering a biodegradable alternative to petrochemical plastics. The intracellular formation and degradation of PHAs is a dynamic process that strongly depends on the availability of carbon and other nutrients. Carbon excess and nitrogen limitation are considered to favor PHA accumulation, whereas carbon limitation triggers PHA depolymerization when all other essential nutrients are present in excess. We studied the population dynamics of Pseudomonas putida KT2440 at the single cell level during different physiological conditions, favoring first PHA polymerization during growth on octanoic acid, and then PHA depolymerization during carbon limitation. PHAs accumulate intracellularly in granules, and were proposed to separate preferentially together with nucleic acids, leading to two daughter cells containing approximately equal amounts of PHA. However, we could show that such P. putida KT2440 cells show bistable behavior when exposed to carbon limitation, and separate into two subpopulations: one with high and one with low PHA. This suggests an asymmetric PHA distribution during cell division under carbon limitation, which has a significant influence on our understanding of PHA mobilization. - Numerical optimal control of turbodynamic ventricular assist devicesItem type: Journal Article
BioengineeringAmacher, Raffael; Asprion, Jonas; Ochsner, Gregor; et al. (2014)The current paper presents a methodology for the derivation of optimal operating strategies for turbo dynamic ventricular assist devices (tVADs). In current clinical practice, tVADs are typically operated at a constant rotational speed, resulting in a blood flow with a low pulsatility. Recent research in the field has aimed at optimizing the interaction between the tVAD and the cardiovascular system by using predefined periodic speed profiles. In the current paper, we avoid the limitation of using predefined profiles by formulating an optimal-control problem based on a mathematical model of the cardiovascular system and the tVAD. The optimal-control problem is solved numerically, leading to cycle-synchronized speed profiles, which are optimal with respect to an arbitrary objective. Here, an adjustable trade-off between the maximization of the flow through the aortic valve and the minimization of the left-ventricular stroke work is chosen. The optimal solutions perform better than constant-speed or sinusoidal-speed profiles for all cases studied. The analysis of optimized solutions provides insight into the optimized interaction between the tVAD and the cardiovascular system. The numerical approach to the optimization of this interaction represents a powerful tool with applications in research related to tVAD control. Furthermore, patient-specific, optimized VAD actuation strategies can potentially be derived from this approach. - Comparative Assessment of the Mechanical Response to Different Screw Dimensions in Scaphoid Fracture FixationItem type: Journal Article
BioengineeringRothenfluh, Esin; Jain, Sambhav; Taylor, William R.; et al. (2025)The scaphoid is the most commonly fractured carpal bone. Headless compression screws became the gold standard for fixation, but the ideal screw diameter remains debated. This study investigates the relative benefit of using a larger screw diameter to improve stability in typical scaphoid fractures. It also examines the effects of preload and screw length on mechanical behaviour. A finite element (FE) model of a mid-waist scaphoid fracture was created. Screws from Medartis (1.7 mm, 2.2 mm, and 3.0 mm diameter; 23 mm length) were placed along the longitudinal axis. Boundary and loading conditions matched prior studies. Interfragmentary displacement (IFD) and von Mises stress were compared across screw sizes. The effects of screw length and preload were also evaluated. Maximum in-plane IFD was 2.08 mm (1.7 mm screw), 0.53 mm (2.2 mm), and 0.27 mm (3.0 mm). The 1.7 mm screw exceeded the scaphoid’s average ultimate stress (60.51 MPa). Increasing preload reduced IFD, especially above 60 N. Screws longer than 1.5 times the mid-waist diameter offered no added benefit. Larger screws provide better biomechanical fracture stability. However, the gain from 2.2 mm to 3.0 mm is minor, while 1.7 mm screws lack sufficient strength. The 2.2 mm screw offers a good balance of stability and bone preservation, making it the preferred choice. - Effectiveness of Remote PPG Construction Methods: A Preliminary AnalysisItem type: Journal Article
BioengineeringHaugg, Fridolin; Elgendi, Mohamed; Menon, Carlo (2022)The contactless recording of a photoplethysmography (PPG) signal with a Red-Green-Blue (RGB) camera is known as remote photoplethysmography (rPPG). Studies have reported on the positive impact of using this technique, particularly in heart rate estimation, which has led to increased research on this topic among scientists. Therefore, converting from RGB signals to constructing an rPPG signal is an important step. Eight rPPG methods (plant-orthogonal-to-skin (POS), local group invariance (LGI), the chrominance-based method (CHROM), orthogonal matrix image transformation (OMIT), GREEN, independent component analysis (ICA), principal component analysis (PCA), and blood volume pulse (PBV) methods) were assessed using dynamic time warping, power spectrum analysis, and Pearson’s correlation coefficient, with different activities (at rest, during exercising in the gym, during talking, and while head rotating) and four regions of interest (ROI): the forehead, the left cheek, the right cheek, and a combination of all three ROIs. The best performing rPPG methods in all categories were the POS, LGI, and OMI methods; each performed well in all activities. Recommendations for future work are provided. - Localized Refractive Changes Induced by Symmetric and Progressive Asymmetric Intracorneal Ring Segments Assessed with a 3D Finite-Element ModelItem type: Journal Article
BioengineeringGarcía de Oteyza, Gonzalo; Álvarez de Toledo, Juan; Barraquer, Rafael I.; et al. (2023)To build a representative 3D finite element model (FEM) for intracorneal ring segment (ICRS) implantation and to investigate localized optical changes induced by different ICRS geometries, a hyperelastic shell FEM was developed to compare the effect of symmetric and progressive asymmetric ICRS designs in a generic healthy and asymmetric keratoconic (KC) cornea. The resulting deformed geometry was assessed in terms of average curvature via a biconic fit, sagittal curvature (K), and optical aberrations via Zernike polynomials. The sagittal curvature map showed a locally restricted flattening interior to the ring (Kmax −11 to −25 dpt) and, in the KC cornea, an additional local steepening on the opposite half of the cornea (Kmax up to +1.9 dpt). Considering the optical aberrations present in the model of the KC cornea, the progressive ICRS corrected vertical coma (−3.42 vs. −3.13 µm); horizontal coma (−0.67 vs. 0.36 µm); and defocus (2.90 vs. 2.75 µm), oblique trefoil (−0.54 vs. −0.08 µm), and oblique secondary astigmatism (0.48 vs. −0.09 µm) aberrations stronger than the symmetric ICRS. Customized ICRS designs inspired by the underlying KC phenotype have the potential to achieve more tailored refractive corrections, particularly in asymmetric keratoconus patterns. - Advantages of Additive Manufacturing for Biomedical Applications of PolyhydroxyalkanoatesItem type: Review Article
BioengineeringGiubilini, Alberto; Bondioli, Federica; Messori, Massimo; et al. (2021)In recent years, biopolymers have been attracting the attention of researchers and specialists from different fields, including biotechnology, material science, engineering, and medicine. The reason is the possibility of combining sustainability with scientific and technological progress. This is an extremely broad research topic, and a distinction has to be made among different classes and types of biopolymers. Polyhydroxyalkanoate (PHA) is a particular family of polyesters, synthetized by microorganisms under unbalanced growth conditions, making them both bio-based and biodegradable polymers with a thermoplastic behavior. Recently, PHAs were used more intensively in biomedical applications because of their tunable mechanical properties, cytocompatibility, adhesion for cells, and controllable biodegradability. Similarly, the 3D-printing technologies show increasing potential in this particular field of application, due to their advantages in tailor-made design, rapid prototyping, and manufacturing of complex structures. In this review, first, the synthesis and the production of PHAs are described, and different production techniques of medical implants are compared. Then, an overview is given on the most recent and relevant medical applications of PHA for drug delivery, vessel stenting, and tissue engineering. A special focus is reserved for the innovations brought by the introduction of additive manufacturing in this field, as compared to the traditional techniques. All of these advances are expected to have important scientific and commercial applications in the near future. - Evaluation of Load on Cervical Disc Prosthesis by Imposing Complex Motion: Multiplanar Motion and Combined Rotational–Translational MotionItem type: Journal Article
BioengineeringAnsaripour, Hossein; Ferguson, Stephen J.; Flohr, Markus (2024)(1) Background: The kinematic characteristics of disc prosthesis undergoing complex motion are not well understood. Therefore, examining complex motion may provide an improved understanding of the post-operative behavior of spinal implants. (2) Methods: The aim of this study was to develop kinematic tests that simulate multiplanar motion and combined rotational–translational motion in a disc prosthesis. In this context, five generic zirconia-toughened alumina (BIOLOX®delta, CeramTec, Germany) ball and socket samples were tested in a 6 DOF spine simulator under displacement control with an axial compressive force of 100 N in five motion modes: (1) flexion–extension (FE = ± 7.5°), (2) lateral bending (LB = ± 6°), (3) combined FE-LB (4) combined FE and anteroposterior translation (AP = 3 mm), and (5) combined LB and lateral motion (3 mm). For combined rotational–translational motion, two scenarios were analyzed: excessive translational movement after sample rotation (scenario 1) and excessive translational movement during rotation (scenario 2). (3) Results: For combined FE-LB, the resultant forces and moments were higher compared to the unidirectional motion modes. For combined rotational–translational motion (scenario 1), subluxation occurred at FE = 7.5° with an incremental increase in AP translation = 1.49 ± 0.18 mm, and LB = 6° with an incremental increase of lateral translation = 2.22 ± 0.16 mm. At the subluxation point, the incremental increase in AP force and lateral force were 30.4 ± 3.14 N and 40.8 ± 2.56 N in FE and LB, respectively, compared to the forces at the same angles during unidirectional motion. For scenario 2, subluxation occurred at FE = 4.93° with an incremental increase in AP translation = 1.75 mm, and LB = 4.52° with an incremental increase in lateral translation = 1.99 mm. At the subluxation point, the incremental increase in AP force and lateral force were 39.17 N and 38.94 N in FE and LB, respectively, compared to the forces in the same angles during the unidirectional motion. (4) Conclusions: The new test protocols improved the understanding of in vivo-like behavior from in vitro testing. Simultaneous translation–rotation motion was shown to provoke subluxation at lower motion extents. Following further validation of the proposed complex motion testing, these new methods can be applied future development and characterization of spinal motion-preserving implants. - First Insights in the Relationship between Lower Limb Anatomy and Back Squat Performance in Resistance-Trained Males and FemalesItem type: Journal Article
BioengineeringKnopfli, Céline; Achermann, Basil; Oberhofer, Katja; et al. (2023)Identifying key criteria of squat performance is essential to avoiding injuries and optimizing strength training outcomes. To work towards this goal, this study aimed to assess the correlation between lower limb anatomy and back squat performance during a set-to-exhaustion in resistance-trained males and females. Optical motion captures of squat performance and data from magnetic resonance imaging (MRI) of the lower limbs were acquired in eight healthy participants (average: 28.4 years, four men, four women). It was hypothesized that there is a correlation between subject-specific musculoskeletal and squat-specific parameters. The results of our study indicate a high correlation between the summed volume of the hamstrings and quadriceps and squat depth normalized to thigh length (r = −0.86), and a high correlation between leg size and one-repetition maximum load (r = 0.81), respectively. Thereby, a marked difference was found in muscle volume and one-repetition maximum load between males and females, with a trend of females squatting deeper. The present study offers new insights for trainers and athletes for targeted musculoskeletal conditioning using the squat exercise. It can be inferred that greater muscle volume is essential to achieving enhanced power potential, and, consequently, a higher 1RM value, especially for female athletes that tend to squat deeper than their male counterparts. - Feature–Classifier Pairing Compatibility for sEMG Signals in Hand Gesture Recognition under Joint Effects of Processing ProceduresItem type: Journal Article
BioengineeringAsfour, Mohammed; Menon, Carlo; Jiang, Xianta (2022)Gesture recognition using surface electromyography (sEMG) serves many applications, from human–machine interfaces to prosthesis control. Many features have been adopted to enhance recognition accuracy. However, studies mostly compare features under a prechosen feature window size or a classifier, biased to a specific application. The bias is evident in the reported accuracy drop, around 10%, from offline gesture recognition in experiment settings to real-time clinical environment studies. This paper explores the feature–classifier pairing compatibility for sEMG. We demonstrate that it is the primary determinant of gesture recognition accuracy under various window sizes and normalization ranges, thus removing application bias. The proposed pairing ranking provides a guideline for choosing the proper feature or classifier in future research. For instance, random forest (RF) performed best, with a mean accuracy of around 74.0%; however, it was optimal with the mean absolute value feature (MAV), giving 86.8% accuracy. Additionally, our ranking showed that the proper pairing enables low-computational models to surpass complex ones. The Histogram feature with linear discriminant analysis classifier (HIST-LDA) was the top pair with 88.6% accuracy. We also concluded that a 1250 ms window and a (−1, 1) signal normalization were the optimal procedures for gesture recognition on the used dataset. - Assessing and Resolving Model Misspecifications in Metabolic Flux AnalysisItem type: Journal Article
BioengineeringGunawan, Rudiyanto; Hutter, Sandro (2017)Metabolic flux analysis (MFA) is an indispensable tool in metabolic engineering. The simplest variant of MFA relies on an overdetermined stoichiometric model of the cell’s metabolism under the pseudo-steady state assumption to evaluate the intracellular flux distribution. Despite its long history, the issue of model error in overdetermined MFA, particularly misspecifications of the stoichiometric matrix, has not received much attention. We evaluated the performance of statistical tests from linear least square regressions, namely Ramsey’s Regression Equation Specification Error Test (RESET), the F-test, and the Lagrange multiplier test, in detecting model misspecifications in the overdetermined MFA, particularly missing reactions. We further proposed an iterative procedure using the F-test to correct such an issue. Using Chinese hamster ovary and random metabolic networks, we demonstrated that: (1) a statistically significant regression does not guarantee high accuracy of the flux estimates; (2) the removal of a reaction with a low flux magnitude can cause disproportionately large biases in the flux estimates; (3) the F-test could efficiently detect missing reactions; and (4) the proposed iterative procedure could robustly resolve the omission of reactions. Our work demonstrated that statistical analysis and tests could be used to systematically assess, detect, and resolve model misspecifications in the overdetermined MFA.
Publications 1 - 10 of 22