Metabolite-Cycled, ECG-Triggered and Navigator-Gated 1H MRS With Optimised Image-Based B0 Shimming Achieves High Spectral Quality In the Myocardium at 3T
dc.contributor.author
Cameron, Donnie
dc.contributor.author
Fillmer, Ariane
dc.contributor.author
Hock, Andreas
dc.contributor.author
Redpath, Thomas W.
dc.contributor.author
Frenneaux, Michael P.
dc.contributor.author
Dawson, Dana
dc.contributor.author
Henning, Anke
dc.date.accessioned
2017-06-11T04:23:30Z
dc.date.available
2017-06-11T04:23:30Z
dc.date.issued
2013
dc.identifier.isbn
978-1-62993-102-9
dc.identifier.uri
http://hdl.handle.net/20.500.11850/79780
dc.language.iso
en
dc.publisher
Curran
dc.title
Metabolite-Cycled, ECG-Triggered and Navigator-Gated 1H MRS With Optimised Image-Based B0 Shimming Achieves High Spectral Quality In the Myocardium at 3T
dc.type
Other Conference Item
ethz.book.title
21st Annual ISMRM Scientific Meeting and Exhibition 2013 : Discovery, Innovation & Application – Advancing MR for Improved Health : Salt Lake City, Utah, USA, 20-26 April 2013
ethz.pages.start
2149
ethz.pages.end
2149
ethz.event
21st Annual ISMRM Scientific Meeting and Exhibition 2013
ethz.event.location
Salt Lake City, UT, USA
ethz.event.date
April 20-26, 2013
ethz.publication.place
Red Hook, NY
ethz.publication.status
published
ethz.leitzahl
03656 - Bösiger, Peter
ethz.leitzahl
ETH Zürich::00002 - ETH Zürich::00012 - Lehre und Forschung::00007 - Departemente::02140 - Dep. Inf.technologie und Elektrotechnik / Dep. of Inform.Technol. Electrical Eng.::02631 - Institut für Biomedizinische Technik / Institute for Biomedical Engineering::03628 - Prüssmann, Klaas P. / Prüssmann, Klaas P.
ethz.leitzahl.certified
03656 - Bösiger, Peter
ethz.leitzahl.certified
ETH Zürich::00002 - ETH Zürich::00012 - Lehre und Forschung::00007 - Departemente::02140 - Dep. Inf.technologie und Elektrotechnik / Dep. of Inform.Technol. Electrical Eng.::02631 - Institut für Biomedizinische Technik / Institute for Biomedical Engineering::03628 - Prüssmann, Klaas P. / Prüssmann, Klaas P.
ethz.date.deposited
2017-06-11T04:24:45Z
ethz.source
ECIT
ethz.identifier.importid
imp593651933963c18681
ethz.ecitpid
pub:125211
ethz.eth
yes
ethz.availability
Metadata only
ethz.rosetta.installDate
2017-07-26T04:02:19Z
ethz.rosetta.lastUpdated
2020-02-14T13:11:42Z
ethz.rosetta.exportRequired
true
ethz.rosetta.versionExported
true
ethz.COinS
ctx_ver=Z39.88-2004&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.atitle=Metabolite-Cycled,%20ECG-Triggered%20and%20Navigator-Gated%201H%20MRS%20With%20Optimised%20Image-Based%20B0%20Shimming%20Achieves%20High%20Spectral%20Quality%20In%20the%&rft.date=2013&rft.spage=2149&rft.epage=2149&rft.au=Cameron,%20Donnie&Fillmer,%20Ariane&Hock,%20Andreas&Redpath,%20Thomas%20W.&Frenneaux,%20Michael%20P.&rft.isbn=978-1-62993-102-9&rft.genre=unknown&rft.btitle=21st%20Annual%20ISMRM%20Scientific%20Meeting%20and%20Exhibition%202013%20:%20Discovery,%20Innovation%20&%20Application%20%E2%80%93%20Advancing%20MR%20for%20Improved%20He
Files in this item
Files | Size | Format | Open in viewer |
---|---|---|---|
There are no files associated with this item. |
Publication type
-
Other Conference Item [18988]