Search
Results
-
Computational models steering the personalization of targeted spinal cord stimulation to restore motor function in humans with spinal cord injury
(2018)Neuroscience 2018 AbstractsOther Conference Item -
Robust Experimental Evaluation Method for the Safety Assessment of Implants with Respect to RF-Induced Heating during MRI
(2017)Proceedings of the 32nd International Union of Radio Science General Assembly and Scientific Symposium (URSI GASS)Other Conference Item -
Power to temperature transfer function derivation for AIMD local tissue heating
(2017)Proceedings of the XXXIInd URSI General Assembly in Montreal (August 2017)Other Conference Item -
A Radio Frequency Radiation Reverberation Chamber Exposure System for Rodents
(2008)Other Conference Item -
Measurement of the absorbed power density of 5G millimeter wave mobile devices
(2022)The latest safety guidelines for the protection of humans from electromagnetic fields (EMF) define new basic restrictions for the millimeter-wave (mm-wave) frequency range in terms of absorbed power density (APD). Therefore, demonstrating the compliance of 5G communication systems requires the assessment of this new figure of merit. In this study, we propose a method for measuring APD in the 5G mm-wave bands that can be integrated into ...Other Conference Item -
Validation Validation of Human Models: Anatomy, Tissue Parameters and Tissue Models
(2014)Proceedings of the ASME 2014 Verification and Validation Symposium, Las VegasOther Conference Item -
A Pipeline for Personalized Brain Modeling: From Stimulation to Network Activity
(2023)BioEM 2023 - Abstract CollectionNeurological and psychiatric disorders are the leading cause of disability worldwide. Personalized computational modeling is a powerful method for probing whole brain network dynamics in both health and disease, and for creating optimized brain stimulation-based therapies. To this end, we developed an automated patient-specific modeling pipeline starting from structural magnetic resonance imaging (MRI) scans, and resulting in a 16 tissue, ...Other Conference Item -
Traceable Absorbed Power Density Assessment System in the 28 GHz Band
(2023)BioEM 2023 - Abstract CollectionICNIRP and IEEE closed a critical gap in the safety guidelines by introducing a basic dosimetric restriction above 6 GHz. These are the absorbed power density (APD) and the spatial averaged power density. In previous work by our group, a phantom and a compatible probe were developed to measure the APD in the 5G new radio frequency range 2 (NR FR2; 24–30 GHz). Here, an experimental validation procedure for the proposed phantom is detailed. ...Other Conference Item