Search
Results
-
Measurement of J/ψ and ψ(2S) Prompt Double-Differential Cross Sections in pp Collisions at √s=7 TeV
(2015)Physical Review LettersThe double-differential cross sections of promptly produced J/ψ and ψ(2S) mesons are measured in pp collisions at √s=7 TeV, as a function of transverse momentum pT and absolute rapidity |y|. The analysis uses J/ψ and ψ(2S) dimuon samples collected by the CMS experiment, corresponding to integrated luminosities of 4.55 and 4.90 fb−1, respectively. The results are based on a two-dimensional analysis of the dimuon invariant mass and decay ...Journal Article -
Observation of a peaking structure in the J/ψφ mass spectrum from B±→J/ψφK± decays
(2014)Physics Letters BA peaking structure in the J/ψφ mass spectrum near threshold is observed in B ±→J/ψφK± decays, produced in pp collisions at √s=7 TeV collected with the CMS detector at the LHC. The data sample, selected on the basis of the dimuon decay mode of the J/ψ, corresponds to an integrated luminosity of 5.2 fb-1. Fitting the structure to an S-wave relativistic Breit-Wigner lineshape above a three-body phase-space nonresonant component gives a ...Journal Article -
Inclusive search for a vector-like T quark with charge 2/3 in pp collisions at sqrt(s) = 8 TeV
(2014)Physics Letters BA search is performed for a massive new vector-like quark T, with charge 2/3, that is pair produced together with its antiparticle in proton–proton collisions. The data were collected by the CMS experiment at the Large Hadron Collider in 2012 at s=8TeV and correspond to an integrated luminosity of 19.5fb−1. The T quark is assumed to decay into three different final states, bW, tZ, and tH. The search is carried out using events with at ...Journal Article -
The performance of the CMS muon detector in proton-proton collisions at √s= 7 TeV at the LHC
(2013)Journal of InstrumentationThe performance of all subsystems of the CMS muon detector has been studied by using a sample of proton-proton collision data at √s = 7 TeV collected at the LHC in 2010 that corresponds to an integrated luminosity of approximately 40 pb-1. The measured distributions of the major operational parameters of the drift tube (DT), cathode strip chamber (CSC), and resistive plate chamber (RPC) systems met the design specifications. The spatial ...Journal Article -
Energy calibration and resolution of the CMS electromagnetic calorimeter in pp collisions at √s = 7 TeV
(2013)Journal of InstrumentationThe energy calibration and resolution of the electromagnetic calorimeter (ECAL) of the CMS detector have been determined using proton-proton collision data from LHC operation in 2010 and 2011 at a centre-of-mass energy of √s = 7 TeV with integrated luminosities of about 5\fbinv. Crucial aspects of detector operation, such as the environmental stability, alignment, and synchronization, are presented. The in-situ calibration procedures are ...Journal Article