Metadata only
Author
Show all
Date
2021-04Type
- Journal Article
Citations
Cited 10 times in
Web of Science
Cited 10 times in
Scopus
ETH Bibliography
yes
Altmetrics
Abstract
Purpose
Spiral readouts combine several favorable properties that promise superior net sensitivity for diffusion imaging. The purpose of this study is to verify the signal‐to‐noise ratio (SNR) benefit of spiral acquisition in comparison with current echo‐planar imaging (EPI) schemes.
Methods
Diffusion‐weighted in vivo brain data from three subjects were acquired with a single‐shot spiral sequence and several variants of single‐shot EPI, including full‐Fourier and partial‐Fourier readouts as well as different diffusion‐encoding schemes. Image reconstruction was based on an expanded signal model including field dynamics obtained by concurrent field monitoring. The effective resolution of each sequence was matched to that of full‐Fourier EPI with 1 mm nominal resolution. SNR maps were generated by determining the noise statistics of the raw data and analyzing the propagation of equivalent synthetic noise through image reconstruction. Using the same approach, maps of noise amplification due to parallel imaging (g‐factor) were calculated for different acceleration factors.
Results
Relative to full‐Fourier EPI at b = 0 s/mm2, spiral acquisition yielded SNR gains of 42‐88% and 40‐89% in white and gray matter, respectively, depending on the diffusion‐encoding scheme. Relative to partial‐Fourier EPI, the gains were 36‐44% and 34‐42%. Spiral g‐factor maps exhibited less spatial variation and lower maxima than their EPI counterparts.
Conclusion
Spiral readouts achieve significant SNR gains in the order of 40‐80% over EPI in diffusion imaging at 3T. Combining systematic effects of shorter echo time, readout efficiency, and favorable g‐factor behavior, similar benefits are expected across clinical and neurosciences uses of diffusion imaging. Show more
Publication status
publishedExternal links
Journal / series
Magnetic Resonance in MedicineVolume
Pages / Article No.
Publisher
WileySubject
Diffusion MRI; Echo-planar imaging; G-factor; Point spread function; Signal-to-noise ratio; Spiral readoutOrganisational unit
03628 - Prüssmann, Klaas P. / Prüssmann, Klaas P.
Funding
188459 - Performance-based Design for the Retrofit of Piled Foundations of Road and Rail Bridges Subjected to Seismic Loading (SNF)
More
Show all metadata
Citations
Cited 10 times in
Web of Science
Cited 10 times in
Scopus
ETH Bibliography
yes
Altmetrics