Show simple item record

dc.contributor.author
Van Praet, Karel M.
dc.contributor.author
Kukucka, Marian
dc.contributor.author
Kofler, Markus
dc.contributor.author
Klein, Christoph
dc.contributor.author
Falk, Volkmar
dc.contributor.author
Unbehaun, Axel
dc.contributor.author
Kempfert, Jörg
dc.date.accessioned
2022-03-31T11:47:33Z
dc.date.available
2022-01-10T04:13:56Z
dc.date.available
2022-03-31T11:47:33Z
dc.date.issued
2021-09-10
dc.identifier.issn
1813-9175
dc.identifier.other
10.1510/mmcts.2021.050
en_US
dc.identifier.uri
http://hdl.handle.net/20.500.11850/524086
dc.description.abstract
The most common congenital cardiac anomaly, affecting an estimated 0.4-2.25% of the general population, is the bicuspid aortic valve. The "pure" bicuspid aortic valve (non-raphe-type or bicuspid aortic valve type 0) is composed of 2 cusps, morphologically and functionally. The shape of the bicuspid aortic valve annulus is often elliptical, is relatively larger than the tricuspid aortic valves, and probably shows severe eccentric calcification. This situation contributes to the difficulties in selecting the correct type and size of transcatheter heart valve when treating bicuspid aortic valve stenosis. Furthermore, it is often associated with a dilated, horizontal ascending aorta and effaced sinuses. The goal of our video tutorial is to present the contemporary circle method used in preoperative sizing during TAVI procedures in patients with a bicuspid aortic valve as well as certain technical considerations and useful advice. Although annular sizing is the main focus for most patients with a bicuspid aortic valve, some patients may need the supra-annular level of sizing. For a dedicated sizing and positioning approach for the SAPIEN 3 Ultra valve, experts in the field propose the circle method.
en_US
dc.language.iso
en
en_US
dc.publisher
Oxford University Press
en_US
dc.subject
Circle method
en_US
dc.subject
TAVI
en_US
dc.subject
bicuspid aortic valve
en_US
dc.subject
Sizing
en_US
dc.subject
Aortic valve repair
en_US
dc.title
The circle method for preoperative TAVI sizing in a Sievers type 0 stenotic bicuspid aortic valve
en_US
dc.type
Educational Material
ethz.journal.title
Multimedia Manual of Cardiothoracic Surgery
ethz.journal.volume
2021
en_US
ethz.journal.abbreviated
Multimed Man Cardiothorac Surg
ethz.pages.start
1670
en_US
ethz.identifier.scopus
ethz.publication.place
Oxford
en_US
ethz.publication.status
published
en_US
ethz.date.deposited
2022-01-10T04:14:04Z
ethz.source
SCOPUS
ethz.eth
yes
en_US
ethz.availability
Metadata only
en_US
ethz.rosetta.installDate
2022-03-31T11:47:44Z
ethz.rosetta.lastUpdated
2023-02-07T00:38:09Z
ethz.rosetta.versionExported
true
ethz.COinS
ctx_ver=Z39.88-2004&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.atitle=The%20circle%20method%20for%20preoperative%20TAVI%20sizing%20in%20a%20Sievers%20type%200%20stenotic%20bicuspid%20aortic%20valve&rft.jtitle=Multimedia%20Manual%20of%20Cardiothoracic%20Surgery&rft.date=2021-09-10&rft.volume=2021&rft.spage=1670&rft.issn=1813-9175&rft.au=Van%20Praet,%20Karel%20M.&Kukucka,%20Marian&Kofler,%20Markus&Klein,%20Christoph&Falk,%20Volkmar&rft.genre=unknown&rft_id=info:doi/10.1510/mmcts.2021.050&
 Search print copy at ETH Library

Files in this item

FilesSizeFormatOpen in viewer

There are no files associated with this item.

Publication type

Show simple item record